The Bosch Rexroth COMPACT LIN. BUSH. KBC-10-NR (R065801030) is a compact linear bushing engineered for general requirements, offering a balance of durability and performance in a highly compact form. This model is characterized by its small outer dimensions, which contribute to its space-saving construction, making it suitable for applications where installation space is limited. It features segmental load-bearing plates with ball conformity in the running track, ensuring high dynamic load ratings and an extended service life. The COMPACT LIN. BUSH. KBC-10-NR is designed with rust-resistant materials without seals and comes not greased, catering to environments where contamination must be minimized such as in medical, chemistry, and food industries. Its stainless steel composition and lack of lubrication make it particularly suited for cleanroom applications or those with strict hygiene requirements. With a standard radial clearance, the bushing allows for high travel speeds of up to 5 m/s and ensures ease of mounting due to its simple press-fit installation that does not require additional retention mechanisms. The design includes multiple lubricant reservoirs for extended intervals between lubrication or potentially maintenance-free operation if conditions permit. This model accommodates shaft diameters ranging from 3 to 50 mm and has an integrated metal retainer slightly larger than the outer diameter of the shaft for a secure fit within the housing bore. Its performance specifications include dynamic load capacities that vary based on total travel distance—with adjustments provided for different travel lengths—and static load capacities that ensure stability under stationary loads. The COMPACT LIN. BUSH. KBC-10-NR operates effectively within a permissible ambient temperature range of -30°C to +80°C, maintaining functionality across diverse environmental conditions. It's also optimized for low friction operation with coefficients as low as 0.01 under certain conditions while providing reliable force transmission with minimal frictional drag even when wiper seals are integrated. Weighing just 0.1 kg, this linear bushing offers a blend of lightweight design and robustness, making it an excellent choice for various linear motion applications where efficiency and precision are paramount.
Compact LB, 10, without seal, CR, not lubricated
Compact linear bushing
Shaft diameter d = 10
Without seal
Radial clearance: Standard
Version: Rust-resistant
Not greased
Unpacked Weight: 0.013 kg
| Low-cost linear bushing for general requirements |
| Small outer dimensions and highly compact construction |
| High dynamic load rating and long service life due to hardened segmental load-bearing plates with ball conformity in the running track |
| Stainless steel for the medical, chemistry and food industries: Segmental load bearing plates comprising 1.4037 balls made from 1.3541 |
| Integrated wiper seals, external seals or no wiper seals |
| Normal radial clearance |
| Not greased |
| High travel speed (5 m/s) |
| Simple mounting: Just press on – no additional retention needed |
| Many pockets acting as lubricant reservoirs for extended lubrication intervals or lubrication for life |
| Pockets collect any dirt that may have worked its way in to prevent the linear bushing from jamming. |
| Integrated metal retainer about 0.1 mm larger than outer diameter (shaft diameters 12 to 50) for secure fit in housing bore |
| Data Sheet | Download Data Sheet |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Friction force | 0.5 |
| Footnote minimum dynamic load capacity Cmin | The dynamic load capacities are based on a total travel of 100,000 m. When based on 50,000 m, the C values in the table are to be multiplied by 1.26. |
| Friction coefficient μ min. | 0.001 |
| Footnote maximum dynamic load capacity Cmax | The dynamic load capacities are based on a total travel of 100,000 m. When based on 50,000 m, the C values in the table are to be multiplied by 1.26. |
| Rows of balls | 5 |
| Series | Compact (C) |
| Footnote friction force FR | One wiper seal: Multiply value with factor 0.5 |
| Productgroup ID | 17 |
| Maximum dynamic load capacity Cmax | 500 |
| Permissible ambient temperature (max) | |
| Max. acceleration amax | 150 |
| Footnote friction coefficient μ | Friction coefficients of unsealed linear bushings when lubricated with oil. The friction coefficient is lowest under heavy load, but can still be above the specified value even under a low load. |
| Permissible ambient temperature | -10 °C ... +80 °C |
| Outer diameter D | 17 |
| Breakaway force | 1 |
| Permissible ambient temperature (min) | |
| Maximum permissible linear speed vmax | 5 |
| Size D | 17 |
| Length of linear bushing | 26 |
| Friction coefficient μ | 0,001 ... 0,004 |
| Friction force FR footnote 2 | Frictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
| Footnote breakaway force | One wiper seal: Multiply value with factor 0.5 |
| Minimum static load capacity C0min | 330 |
| Maximum static load capacity C0max | 480 |
| Minimum dynamic load capacity Cmin | 420 |
| Shaft diameter d | 10 |
| Linear guide type | Linear bushing and shaft |
| Format of linear bushings | – Closed |
| Filter for linear bushings and shafts | Linear bushings |
| Footnote minimum static load capacity C0min | |
| Friction coefficient μ max. | 0.004 |
| Footnote maximum static load capacity C0max | |
| Weight | 0.013 |
| Size D1 with tolerance | |
| Size C | 26 |
| Radial clearance shaft/bore h6/H7 |
General technical data
|
Ø d |
mm |
8 | 10 | 12 | 14 | 16 | 20 | 25 | 30 | 40 | 50 |
|
amax |
m/s² |
150 | |||||||||
|
vmax |
m/s |
5 | |||||||||
|
m |
kg |
0.011 | 0.014 | 0.016 | 0.018 | 0.025 | 0.028 | 0.058 | 0.08 | 0.14 | 0.17 |
|
FR 1) 2) |
N |
0.4 | 0.5 | 0.8 | 0.9 | 1 | 1.5 | 2 | 2.5 | 3 | 4 |
|
Breakaway force 1) |
N |
0.8 | 1 | 1.5 | 1.8 | 2 | 3 | 4.5 | 6 | 8 | 10 |
|
μ 3) |
0.001 ... 0.004 | ||||||||||
|
Rows of balls |
4 | 5 | 6 | ||||||||
|
Shaft radial clearance h6/bore H7 |
µm |
+ 25 + 2 |
+ 32 0 |
+ 33 - 1 |
+ 36 0 |
+ 42 - 1 |
|||||
|
Operating conditions |
|||||||||||
|
Permissible ambient temperature (min ... max) |
-10 °C ... +80 °C | ||||||||||
| 1) | One wiper seal: Multiply by a factor of 0.5. |
| 2) | Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
| 3) | Friction coefficients of unsealed Linear Bushings when lubricated with oil. The friction coefficient is lowest under heavy load, but can still be above the specified value even under a low load. |
Load capacities and load moments
|
Ød |
mm |
8 | 10 | 12 | 14 | 16 | 20 | 25 | 30 | 40 | 50 |
|
Cmin |
N |
350 | 420 | 510 | 530 | 660 | 780 | 1630 | 2140 | 3520 | 3970 |
|
Cmax |
N |
410 | 500 | 610 | 630 | 780 | 990 | 2050 | 2700 | 4470 | 5030 |
|
C0min |
N |
280 | 330 | 340 | 400 | 480 | 1050 | 1510 | 2510 | 2890 | |
|
C0max |
N |
400 | 480 | 500 | 580 | 720 | 1560 | 2230 | 3720 | 4280 | |
| The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. |
Legend
|
Symbol |
Description |
Unit |
|
Ød |
Shaft diameters |
mm |
|
amax |
Maximum acceleration travel |
m/s2 |
|
Cmax |
Maximum dynamic load rating |
N |
|
Cmin |
Minimum dynamic load rating |
N |
|
C0max |
Maximum static load rating |
N |
|
C0min |
Minimum static load rating |
N |
|
FR |
Friction force |
N |
|
m |
Mass |
kg |
|
vmax |
Maximum permissible speed |
m/s |
|
μ |
Friction coefficient |
Effect of load direction on load rating
The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.
Reduced load capacity with short stroke
In case of short stroke, the service life of the shafts is less than that of Linear Bushings. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .
| 1) | fs = factor |
| 2) | s = stroke |
Definition of dynamic load ratings
Sealing
The sealed version contains integrated wiper seals.
Separate wiper seals are also available (no securing necessary).
Installation
Install the Linear Bushings using an arbor press (see "Notes for mounting" below). If Linear Bushings are slightly skewed when initially installed into the housing bore, they will align themselves as they are pressed in. The Linear Bushing does not have to be removed and realigned.
Retention
Shaft diameter 8 and 10: The plastic outer sleeve is oversized. Additional retention is required for vibrations or high acceleration. Starting from shaft diameter 12: The outer diameter of the metal holding ring is oversized. No additional retention needed (bore length ≥ C).
General mounting instructions
Initial lubrication
Linear bushings do not come with initial lubrication. Grease the Linear Bushings before use. Service life data is based on initial lubrication and relubricated Linear Bushings.
Wiper seals for eLINE Linear Bushings and Compact Linear Bushings
Wiper seals for eLINE Linear Bushings and Compact Linear Bushings
Galvanized metal case Elastomer wiper sealCatalog
Instructions
Service