You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R060030800


$53.43 USD
  • BOSCH REXROTH
  • Material:R060030800
  • Model:KBM-8

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth STD.LINEAR BUSHING KBM-8 (R060030800) is a high-quality standard linear bushing designed for applications requiring robust motion control. This closed-type linear bushing features a rugged all-metal design with a steel ball retainer, making it suitable for harsh environments and heavy contamination conditions often found in woodworking, foundries, and cement plants. The KBM-8 is specifically crafted without seals to allow for higher permissible ambient temperatures and is equipped with many pockets that act as lubricant reservoirs, potentially extending lubrication intervals or even enabling lubrication for life. The steel ball retainer is designed to accommodate shaft diameters of varying sizes, with plastic strips made of POM for certain diameters and PA for others. These materials provide durability and smooth motion. The integrated steel retaining rings within the bushing contribute to its ability to withstand higher temperatures, especially with larger shaft diameters. The hardened and ground outer sleeve ensures reliable performance while maintaining the integrity of the motion control system. This linear bushing has multiple rows of balls made from rolling bearing steel that are capable of handling dynamic and static loads efficiently. With its advanced design, the KBM-8 can prevent dirt from jamming the mechanism by collecting any particulates in its pockets. It provides a maximum dynamic load capacity (Cmax) and features a friction coefficient range that varies depending on load conditions. Bosch Rexroth's attention to detail in the engineering of this linear bushing ensures minimal friction force under radial load, contributing to efficient operation. The product offers an impressive breakaway force and maximum permissible linear speed (vmax), making it an excellent choice for various industrial applications where precision linear movement is critical. With a weight of 0.1 kg, this robust component maintains performance across a wide range of operating temperatures without compromising on quality or reliability.


Standard LB, closed, 8, without seal

Standard linear bushing
Standard (metal)
Closed
Shaft diameter d = 8
Without seal
Version: Standard

Unpacked Weight: 0.0168 kg
Rugged all-metal design with steel ball retainer for harsh environments and heavy contamination
Many pockets acting as lubricant reservoirs for extended lubrication intervals or lubrication for life
Steel ball retainer (shaft diameters 3, 4 and 10 with plastic strip made of POM and shaft diameters 5 and 8 made of PA)
Closed, for self-supporting shafts
Balls made of rolling bearing steel
For use in woodworking, foundries, cement plants
Pockets collect any dirt that may have worked its way in to prevent the linear bushing from jamming.
No wiper seals, come with integrated steel retaining rings; higher temperatures allowed with shaft diameters 12 and higher
Hardened and ground outer sleeve
Rows of balls4
Footnote shaft radial clearance h6Determined from working bore diameter and shaft tolerance statistics. Recommended housing bore tolerance: H6 or H7.
SeriesStandard (metal)
Footnote friction force FROne wiper seal: Multiply value with factor 0.5
Size C1 H1316.2
Maximum dynamic load capacity Cmax370
Footnote permissible ambient temperature (min ... max)Higher temperatures are only admissible at linear bushings without wiper seals with ball retainers made of steel. Make allowance for reductions in load capacity.
Max. acceleration amax100
Footnote friction coefficient μFriction coefficients of unsealed linear bushings when lubricated with oil. The friction coefficient is lowest under heavy load, but can still be above the specified value even under a low load.
Permissible ambient temperature-10 °C ... +80 °C
Outer diameter D16
Breakaway force1
Maximum permissible linear speed vmax2.5
Size D16
Size D114.7
Friction coefficient μ0,001 ... 0,004
Size C h1225
Size C21.1
Friction coefficient μ max.0.004
Friction force0.5
Footnote minimum dynamic load capacity CminThe dynamic load capacities are based on a total travel of 100,000 m. When based on 50,000 m, the C values in the table are to be multiplied by 1.26.
Friction coefficient μ min.0.001
Footnote maximum dynamic load capacity CmaxThe dynamic load capacities are based on a total travel of 100,000 m. When based on 50,000 m, the C values in the table are to be multiplied by 1.26.
Productgroup ID17
Permissible ambient temperature (max)+80
Permissible ambient temperature (min)-10
Friction force FR footnote 2Frictional drags generated by linear bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.
Footnote breakaway forceOne wiper seal: Multiply value with factor 0.5
Minimum static load capacity C0min240
Maximum static load capacity C0max330
Minimum dynamic load capacity Cmin320
Shaft diameter d8
Linear guide typeLinear bushing and shaft
Filter for linear bushings and shaftsLinear bushings
Format of linear bushings– Closed
Footnote minimum static load capacity C0min
Footnote maximum static load capacity C0max
Weight0.0168
Size D1 with tolerance14.7 mm

General technical data

Ø d

mm

3 4 5 8 10 12 16 20 25 30 40 50 60 80

amax

m/s²

100 50

vmax

m/s

2.5 2

m

kg

0.001 0.002 0.01 0.02 0.03 0.04 0.05 0.1 0.19 0.32 0.62 1.14 2.11 4.7

FR

N

- 0.4 1) 2) 0.5 1) 2) 1 1) 2) 2 1) 2) 3 1) 2) 4 1) 2) 5 1) 2) 6 1) 2) 8 1) 2) 10 1) 2) 12 1) 2) 15 1) 2)

Breakaway force

N

- 0.8 1) 1 1) 2 1) 6 1) 9 1) 12 1) 14 1) 18 1) 24 1) 30 1) 36 1) 45 1)

μ 3)

0.001 ... 0.004

Rows of balls

4 5 6

Working bore diameter tolerance

µm

+ 8
0
+ 11
+ 1
+ 12
+ 2
+ 8
0
+ 12
+ 2
+ 14
+ 2
+ 16
+ 2
+ 19
+ 2
+ 24
+ 2

Shaft radial clearance h6 4)

µm

+ 12
+ 2
+ 14
+ 2
+ 16
+ 4
+ 18
+ 5
+ 20
+ 5
+ 22
+ 5
+ 23
+ 6
+ 25
+ 6
+ 30
+ 7
+ 33
+ 7
+ 37
+ 8

Operating conditions

Permissible ambient temperature (min ... max) 5)

-10 °C ... +80 °C
1) One wiper seal: Multiply by a factor of 0.5.
2) Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.
3) Friction coefficients of unsealed Linear Bushings when lubricated with oil. The friction coefficient is lowest under heavy load, but can still be above the specified value even under a low load.
4) Determined from working bore diameter and shaft tolerance statistics. Recommended housing bore tolerance: H6 or H7.
5) Only unsealed Linear Bushings with steel ball retainers may be used at higher temperatures. Make allowance for reductions in load capacity.

Load capacities and load moments

Ød

mm

3 4 5 8 10 12 16 20 25 30 40 50 60 80

Cmin

N

55 70 180 320 300 420 580 1170 2080 2820 5170 8260 11500 21000

Cmax

N

65 80 210 370 350 480 670 1390 2480 2980 5480 8740 12100 22200

C0min

N

45 60 140 240 260 280 440 860 1560 2230 3810 6470 9160 16300

C0max

N

65 85 200 330 370 400 620 1250 2280 2860 4880 8280 11730 20850
The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the  values in the table need to be multiplied by 1.26.

Legend

Symbol

Description

Unit

Ød

Shaft diameters

mm

amax

Maximum acceleration travel

m/s2

Cmax

Maximum dynamic load rating

N

Cmin

Minimum dynamic load rating

N

C0max

Maximum static load rating

N

C0min

Minimum static load rating

N

FR

Friction force

N

m

Mass

kg

vmax

Maximum permissible speed

m/s

μ

Friction coefficient

Impact of load direction on load rating of closed Linear Bushings

The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.

 

technical illustration-R060030800-Standard LB, closed, 8, without seal

Definition of dynamic load ratings

Installation dimensions/interchangeability

Standard Linear Bushings have the same installation dimensions as super Linear Bushings. They are interchangeable, differ however in terms of securing, radial clearance, load ratings and lubrication.

Sealing

Standard Linear Bushings come with a wiper seal with shaft diameters of 5 and higher. Open standard Linear Bushings with shaft diameters 20 to 80 can also come fully sealed (with longitudinal seal; increased friction).

technical illustration-R060030800-Standard LB, closed, 8, without seal

Dimensions

Ød

mm

3 4 5 8 10 12 16 20 25 30 40 50 60 80

D

mm

7 8 12 16 19 22 26 32 40 47 62 75 90 120

C

h12

mm

10 12 22 25 29 32 36 45 58 68 80 100 125 165

C1

H13

mm

- 14.2 16.2 21.6 22.6 24.6 31.2 43.7 51.7 60.3 77.3 101.3 133.3

C2

mm

- 1.1 1.3 1.6 1.85 2.15 2.65 3.15 4.15

D1

mm

- 11.1 14.7 18 20.5 24.9 30.5 38.5 44.5 58 71 85 114

Life expectancy calculation

General mounting instructions

Customer-built housings

Initial lubrication

Linear bushings do not come with initial lubrication. Grease the Linear Bushings before use. Service life data is based on initial lubrication and relubricated Linear Bushings.

technical illustration-R060030800-Standard LB, closed, 8, without seal

Lubrication

Directives and standards

Notes