The Bosch Rexroth HM 20-2X/315-F-C13-05-N (R901342038) is a high-precision pressure transducer designed for monitoring and controlling hydraulic pressures within a wide range of applications. This sensor is capable of measuring pressures with ranges up to 600 bar, making it suitable for various demanding environments where accurate pressure readings are critical. The transducer features a thin film measuring cell and components that come into contact with media are constructed from stainless steel, ensuring durability and compatibility with a variety of fluids. With its excellent non-repeatability of less than 0.1% and an accuracy class of 0.5, the HM 20-2X/315-F-C13-05-N provides reliable and precise measurements essential for maintaining system performance and safety. The device also boasts operational safety features including high bursting pressure capacity, reversed polarity protection, overvoltage protection, and short-circuit protection. This model operates within an extensive temperature range, ensuring consistent performance under varying environmental conditions. Additionally, it has received marine approval DNVGL for all variants with current output, which attests to its robustness and suitability for maritime applications. The component series X to which this transducer belongs indicates that it is part of a line designed to handle maximum operating pressures of up to 315 bar. It offers pressure ratings at several intervals including 100, 160, 250, 315, 400, 600 bar etc., providing flexibility for integration into different hydraulic systems. Furthermore, the HM 20-2X/315-F-C13-05-N is cULus-listed demonstrating compliance with North American safety standards and regulations for industrial control equipment.
Pressure transducers are used to monitor and control hydraulic pressures. They transform the measured pressure into a normalized, linear, electrical output signal.
|
01 |
02 |
03 |
04 |
05 |
06 |
||||
|
HM20 |
– |
2X |
/ |
– |
– |
K35 |
|
01 |
Pressure transducer |
HM20 |
|
02 |
Component series 20 ... 29 (20 ... 29: unchanged installation dimensions and pin assignments) |
2X |
|
03 |
10 bar |
10 |
|
50 bar |
50 |
|
|
100 bar |
100 |
|
|
160 bar |
160 |
|
|
250 bar |
250 |
|
|
315 bar |
315 |
|
|
400 bar |
400 |
|
|
630 bar1) |
630 |
|
|
04 |
Current output 4 to 20 mA 2) |
C |
|
Voltage output 0.1 to 10 V |
H |
|
|
05 |
Connector, 4-pole, M12x1 |
K35 |
|
06 |
Without throttle element |
ohne Bez. |
|
Throttle element (corresponds to 0.3 mm nozzle) 3), 4) |
N |
| 1) | Only available with throttle element |
| 2) | With marine approval DNV-GL |
| 3) | Only available for versions with 250, 315, 400 and 630 bar |
| 4) | Highly dynamic effects in like pressure peaks or cavitation in hydraulic systems may damage the measuring cell. For these applications, devices with integrated throttle element [version "-N"] in the process interface have to be used. |
|
Replacement seal ring |
|
|
Designation |
Material number |
|
Seal ring NBR |
R900012467 |
Cable sets or mating connectors are not included in the scope of delivery; please order separately.
General
|
Component series |
2X |
Eingangsgrößen
|
Operating voltage 1) |
US |
16 … 36 VDC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Residual ripple |
UPP |
2.5 V (40 to 400 Hz) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Maximum current consumption 2) |
Imax |
mA |
≤ 12 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Isolation resistance |
R |
MΩ |
> 100 (500 VDC) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Pressure measuring ranges |
pN |
bar |
10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 |
| 1) | With cULus: max. of 30 VDC is admissible |
| 2) | With voltage output |
Output parameters
|
Output signal |
admissible load |
Current |
ISig |
4 … 20 mA, RA = (US - 8.5 V) / 0.0215 A with RA in Ω and US in V | |
|
Voltage |
USig |
0.1 … 10 V, RA > 2 kΩ | |||
|
Setting time (10 ... 90 %) |
t |
ms |
< 1 | ||
|
Accuracy class 1) |
% |
< 0.5 | |||
|
Temperature coefficient |
Zero point and range |
< 0.1 % / 10 K | |||
|
Hysteresis 2) |
% |
< 0.15 | |||
|
Long-term drift (1 year) under reference conditions |
% |
< 0.1 | |||
| 1) | Related to the complete measurement range, including non-linearity, hysteresis, zero point and end value deviation (corresponds to the measuring deviation according to IEC 61298-2) |
| 2) | Related to the temperature range -20 … 80 °C |
Ambient conditions
|
Ambient temperature range |
ϑ |
°C |
-40 … +85 |
|
Storage temperature range |
ϑ |
°C |
-40 … +100 |
|
Hydraulic fluid temperature range |
ϑ |
°C |
-40 … +90 |
Other characteristics
|
Pressure port 1) |
G1/4 according to DIN 3852 form E, seal ring according to DIN 3869-14 | |||
|
Material |
Throttle |
1.4305 | ||
|
Housing |
V4A (1.4404), PEI, HNB | |||
|
in contact with the medium |
1.4542, 1.4305, NBR | |||
|
Pressure media 2) |
HL, HLP, HFC, nitrogen, others upon request | |||
|
Tightening torque range |
Measurement ranges > 400 bar |
MA |
Nm |
20 … 25 |
|
Measurement ranges ≥ 400 bar |
MA |
Nm |
25 … 30 | |
|
Anschlussart |
4-pole M12 connector at the housing | |||
|
Type of protection according to EN 60529 |
IP65 / IP67 with mating connector correctly mounted and locked | |||
|
Weight |
m |
kg |
0.06 | |
|
Life cycle |
60 million load cycles or 60000 h | |||
|
Admissible shock and vibration loads according to DIN EN 60068-2-27 |
15 g / 11 ms / 3 axes | |||
|
Sine test according to DIN EN 60068-2-6:2008 |
10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | |||
|
Noise test according to DIN EN 60068-2-64 |
20 … 2000 Hz / 14 g RMS / 42 g peak / 24 h / 3 axes | |||
|
Electro-magnetic compatibility |
EMC EN 61000-4-2 ESD |
4 kV CD / 8 kV AD with BWK B | ||
|
EMC EN 61000-4-3 HF radiated |
10 V / m (80 ... 2700 MHz) with BWK A | |||
|
EMC EN 61000-4-4 Burst |
2 kV with BWK B | |||
|
EMC EN 61000-4-5 Surge |
1 kV / 42 Ω with BWK B | |||
|
EMC EN 61000-4-6 HF line-bound |
10 Veff (150 kHz ... 80 MHz) with BWK A | |||
|
EMC EN 61000-4-8 Magnetic field 50/60 Hz |
100 A/m with BWK A | |||
|
EMC EN 61000-4-9 Magnetic field pulsed |
1000 A/m with BWK A | |||
|
EMC EN 55016-2-1 Interference voltage |
0.15 ... 30 MHz, class A, EN 55022 | |||
|
EMC EN 55016-2-3 Radio interference field strength |
30 ... 1000 MHz, class B, EN 55022 | |||
|
Conformity |
CE according to the EMC directive | |||
|
Further tests |
cULus-listed | |||
| 1) | Thorough bleeding must be ensured |
| 2) | Maximum of 300 bar is admissible |
For applications outside these parameters, please consult us!
|
Voltage |
Current (two-wire system) |
Values for US, RA and USig, see Technical data
|
Values for US, RA and USig, see Technical data
|
Dimensions in mm
|
1 |
Pressure port G1/4 male thread |
|
2 |
Seal ring |
|
3 |
4-pole M12 connector |
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded
4P M12 +
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded
4P M12 +
For sensors and valves with connector “K24”, “K35” and “K72” Cable sets M12, 4-pole, line cross-section 0.34 mm2Data sheet
Spare parts & repair