BOSCH REXROTH
R053326010
$719.21 USD
- BOSCH REXROTH
- Material:R053326010
- Model:KUM-C60-MFG
Quantity in stock: 0
The Bosch Rexroth BALL TRANSFER UNIT KUM-C60-MFG (R053326010) is a robust and versatile component designed to facilitate the smooth and precise movement of goods across conveyor systems or transfer tables. This ball transfer unit is engineered with a solid steel housing that ensures durability under high loads, making it suitable for various material handling applications. The unit's balls are made from corrosion-resistant steel, providing longevity and consistent performance even in environments where rust and wear could be a concern. Equipped with a felt seal and pre-lubricated, the KUM-C60-MFG ensures that contaminants are kept out while maintaining smooth operation without the need for immediate maintenance. For those requiring alternative sealing options, this unit is also available with a polymer wiper seal. All parts of the unit have been galvanized to further enhance resistance to corrosion and wear. The product has been designed for ease of use, with an outer diameter (D) that allows it to fit seamlessly into existing conveyor systems. It can operate within a temperature range of -30°C to 70°C, but it's important to note that at temperatures above 70°C, only bright metal ball transfer units without a felt seal should be used. Users should also consider using high-temperature lubricant and follow the manufacturer's instructions for maintenance in these conditions. The BALL TRANSFER UNIT KUM-C60-MFG has a static load rating (C0) which indicates its capability to withstand loads without motion. In dynamic applications where movement is constant, the dynamic load capacity (C) becomes relevant; users should be aware that prolonged use at speeds above 1 m/s may lead to increased temperature and reduced service life depending on the load. With its nominal size precision and weight consideration, this ball transfer unit from Bosch Rexroth is an essential component for industries looking for reliable material handling solutions that require minimal downtime and maintenance.
Ball transfer units with felt seal – Size 60
Ball transfer unit with solid steel housing
All parts galvanized, balls made from corrosion-resistant steel
Size = 60
With felt seal, lubricated
Unpacked Weight: 3.677 kg
| With solid steel housing |
| For high loads |
| Alternatively available with polymer wiper seal |
| All parts galvanized |
| Balls made from corrosion-resistant steel 1.3541 / 1.4034 |
| With felt seal |
| Data Sheet | Download Data Sheet |
| 2D CAD | Download 2D CAD |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Productgroup ID | 17 |
| Size b | 14.5 |
| Size a | 13 |
| Maximum operating temperature | |
| Size H | 77.5 |
| Minimum operating temperature | |
| Size h | 29.5 |
| Outer diameter D | 100 |
| Maximum permissible linear speed vmax | 2 |
| Operating temperature | -30 °C ... +100 °C |
| Size D | 100 |
| Size D1 | 117 |
| Tolerance h | |
| Static load rating C0 | 20000 |
| Footnote permissible operating temperature (min...max) | At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
| Dynamic load capacity C | 9700 |
| Footnote operating temperature max. | For temperatures over 100°C, only load balls made from bare metal without a felt seal may be used. Take into account the reduction in load capacity. Use high-temperature lubricant! Follow the instructions of the manufacturer! The existing lubricant oil may have to be washed out. |
| Note: Maximum permissible speed vmax | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life needs to be reckoned with depending on the load. |
| Size dW | 60.325 |
| Weight | 3.677 |
| Tolerance D | |
| Nominal size | 60 |
Technical data
|
Size |
60 | |
|
C |
N |
9700 |
|
C0 |
N |
20000 |
|
vmax 1) |
m/s |
2 |
|
m |
kg |
3.5 |
|
Operating conditions |
||
|
Size |
60 | |
|
Admissible operating temperature (min ... max) 2) |
-30 °C ... +100 °C | |
| 1) | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life needs to be reckoned with depending on the load. |
| 2) | At temperatures above 100 °C, only bright metal load balls without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Note the reduction in load capacity! Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out.
Temperature factor
|
Temperature (°C) |
Temperature factor ft |
|
125 |
0,9 |
|
150 |
0,8 |
|
175 |
0,7 |
|
200 |
0,5 |
The load capacity must be multiplied by the temperature factor.
Legend
|
Symbol |
Description |
Unit |
Picture |
|
C |
Dynamic load capacity |
N |
|
|
C0 |
Static load capacity |
N |
|
|
vmax |
Conveying speed |
m/s |
|
|
m |
Mass |
kg |
Technical data
Applications
General-purpose machines Feed tables for sheet-metal working machines Fixtures for press brakes Feed devices for machining centers Drilling tables and motor-driven supporting tables Assembly aids in the manufacture of large engines and motors Construction of special-purpose machines Aerospace industry Beverages and stone-processing industries Not suitable for use under water
Conveyor systems
Ball transfer tables, turntables and switches for sorting and distribution systems Crossover sections of continuous conveyors Baggage sorting systems at airports Transport of steel tubes and pipes Lifting platforms
Dimensions
|
Size |
dw |
D |
Tolerance for D |
D1 |
h |
Tolerance for h |
H |
a |
b |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
| 60 | 60.325 | 100 | ± 0.11 | 117 | 29.5 | ± 0.2 | 77.5 | 13 | 14.5 |
| 1) | with tolerance ring |
| 2) | Gluing in |
Installation dimensions
|
Size |
with tolerance ring |
Gluing in |
|||||||
|
Part number 1) |
D2 |
Tolerance for D2 |
DE |
Tolerance for DE |
c |
Tolerance for c |
DE |
Tolerance for DE |
|
|
Tolerance ring |
|||||||||
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
||
| 60 | R081010002 | 100.3 | + 0.5 | 102.5 | + 0.35 | 19.1 | + 0.3 | 100.15 | + 0.25 |
| 1) | made from spring strip 1.1248, alternatively 1.8159 |