BOSCH REXROTH
R053000520
$21.63 USD
- BOSCH REXROTH
- Material:R053000520
- Model:KUL-15-MFG
Quantity in stock: 0
The Bosch Rexroth BALL TRANSFER UNIT KUL-15-MFG (R053000520) is a specialized component designed for facilitating smooth and precise movement of goods across ball transfer tables. This unit features a lightweight plastic housing, enhancing its suitability for applications where reduced weight is advantageous. It is equipped with a felt seal and comes pre-lubricated, ensuring reliable operation and longevity. The KUL-15-MFG is specifically tailored for special applications, such as those involving lightweight materials. It can be easily mounted using a quarter-turn fastener, which simplifies the installation process. The product's outer diameter D and size H are meticulously crafted to meet the demands of various systems. With an operating temperature range from C to C, this ball transfer unit maintains functionality under varying environmental conditions. However, it is important to note that at temperatures above C, units without a felt seal should be used instead. In such high-temperature scenarios, users must consider the reduction in load capacity and are advised to use high-temperature lubricant while adhering to the manufacturer's instructions regarding maintenance. The dynamic load capacity C of this unit ensures it can handle the designated loads effectively without compromising performance. When operating at prolonged periods at speeds above m/s, it's crucial to consider potential increases in temperature and reductions in service life dependent on the load being moved. This ball transfer unit has been thoughtfully designed with both functionality and practicality in mind, making it an essential component for efficient material handling in specialized lightweight applications. With its nominal weight of . kg and nominal size specification, the Bosch Rexroth BALL TRANSFER UNIT KUL-15-MFG stands out as a reliable choice for enhancing movement within various systems.
Ball transfer units with felt seal – Size 15
Ball transfer unit with plastic housing (light-weight construction)
Size = 15
With felt seal, lubricated
Unpacked Weight: 0.04336 kg
| With plastic housing |
| For special applications (e.g. for lightweight ball transfer tables) |
| Mounting with quarter-turn fastener |
| Data Sheet | Download Data Sheet |
| 2D CAD | Download 2D CAD |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Productgroup ID | 17 |
| Maximum operating temperature | |
| Size H | 32 |
| Minimum operating temperature | |
| Size h | 2 |
| Outer diameter D | 42 |
| Maximum permissible linear speed vmax | 2 |
| Operating temperature | -30 °C ... +100 °C |
| Size D | 42 |
| Footnote permissible operating temperature (min...max) | At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
| Dynamic load capacity C | 500 |
| Footnote operating temperature max. | At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
| Note: Maximum permissible speed vmax | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life needs to be reckoned with depending on the load. |
| Size dW | 15 |
| Weight | 0.04336 |
| Nominal size | 15 |
Technical data
|
Size |
15 | |
|
C |
N |
500 |
|
vmax 1) |
m/s |
2 |
|
m |
kg |
0.045 |
|
Operating conditions |
||
|
Size |
15 | |
|
Admissible operating temperature (min ... max) 2) |
-30 °C ... +100 °C | |
| 1) | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life needs to be reckoned with depending on the load. |
| 2) | At temperatures above 100 °C, only bright metal load balls without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Note the reduction in load capacity! Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out.
Temperature factor
|
Temperature (°C) |
Temperature factor ft |
|
125 |
0,9 |
|
150 |
0,8 |
|
175 |
0,7 |
|
200 |
0,5 |
The load capacity must be multiplied by the temperature factor.
Legend
|
Symbol |
Description |
Unit |
Picture |
|
C |
Dynamic load capacity |
N |
|
|
vmax |
Conveying speed |
m/s |
|
|
m |
Mass |
kg |
Technical data
Applications
General-purpose machines Feed tables for sheet-metal working machines Fixtures for press brakes Feed devices for machining centers Drilling tables and motor-driven supporting tables Assembly aids in the manufacture of large engines and motors Construction of special-purpose machines Aerospace industry Beverages and stone-processing industries Not suitable for use under water
Conveyor systems
Ball transfer tables, turntables and switches for sorting and distribution systems Crossover sections of continuous conveyors Baggage sorting systems at airports Transport of steel tubes and pipes Lifting platforms
Dimensions
|
Size |
dw |
D |
h |
H |
|
mm |
mm |
mm |
mm |
|
| 15 | 15 | 42 | 2 | 32 |