BOSCH REXROTH
R053611510
$23.96 USD
- BOSCH REXROTH
- Material:R053611510
- Model:KUK-B15-MFG
Quantity in stock: 0
The Bosch Rexroth BALL TRANSFER UNIT KUK-B15-MFG (R053611510) is a high-quality component designed for smooth and precise material handling applications. This unit features a galvanized cover and housing, with balls constructed from antifriction bearing steel, ensuring durability and reliable performance. The ball transfer unit is equipped with a felt seal and comes lubricated, providing a maintenance-friendly solution that can be easily mounted and extracted from the load side. The KUK-B15-MFG model includes spring clips as fastening elements, which allow for flexible tolerances during installation. Its reinforced cover is built to withstand heavy impact loads, making it suitable for robust industrial environments. With an outer diameter D and size specifications that meet precise engineering standards, this unit delivers consistent operation under various conditions. This model has been engineered to operate within a specific temperature range, maintaining functionality between minimum and maximum operating temperatures. For applications requiring higher temperature resilience, Bosch Rexroth advises using bright metal ball transfer units without a felt seal and applying high-temperature lubricant as per the manufacturer's instructions. The BALL TRANSFER UNIT KUK-B15-MFG boasts an impressive static load rating C and dynamic load capacity C1, ensuring it can handle substantial weights with ease. It is also designed to accommodate maximum permissible linear speeds while considering potential reductions in service life during extended periods of use at elevated speeds or loads. Overall, the Bosch Rexroth BALL TRANSFER UNIT KUK-B15-MFG offers a robust solution for facilitating multi-directional movement of goods within various systems, ensuring efficient operation across diverse material handling scenarios.
Ball transfer units with felt seal – Size 15
Ball transfer unit, with clip as fastening element
Galvanized cover and housing, balls made from anti-friction bearing steel
Size = 15
With felt seal, lubricated
Unpacked Weight: 0.042 kg
| With fastening element |
| Easily mountable and extractable from the load side |
| Fixing is by means of spring clips, which permit generous tolerances in the mounting hole |
| Reinforced cover to withstand heavy impact loads |
| Cover and housing galvanized |
| Balls made from antifriction bearing steel 1.3505 |
| Data Sheet | Download Data Sheet |
| 2D CAD | Download 2D CAD |
| 2D CAD | Download 2D CAD |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Tolerance DB | |
| Productgroup ID | 17 |
| Product information | Ball transfer unit with bottom hole on request |
| Size b | 5.5 |
| Maximum operating temperature | |
| Size H | 20 |
| Minimum operating temperature | |
| Size h | 9.5 |
| Outer diameter D | 24 |
| Maximum permissible linear speed vmax | 2 |
| Operating temperature | -30 °C ... +100 °C |
| Size D | 24 |
| Size D1 | 31 |
| Tolerance h | |
| Static load rating C0 | 1000 |
| Footnote permissible operating temperature (min...max) | At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
| Size s | 1.5 |
| Dynamic load capacity C | 500 |
| Size DB | 24 |
| Footnote operating temperature max. | For temperatures over 100°C, only load balls made from bare metal without a felt seal may be used. Take into account the reduction in load capacity. Use high-temperature lubricant! Follow the instructions of the manufacturer! The existing lubricant oil may have to be washed out. |
| Note: Maximum permissible speed vmax | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life is to be expected depending on the load. |
| Size dW | 15.875 |
| Weight | 0.042 |
| Tolerance D | |
| Nominal size | 15 |
Technical data
|
Size |
15 | 22 | 30 | |
|
C |
N |
500 | 1300 | 2500 |
|
C0 |
N |
1000 | 2600 | 5000 |
|
vmax 1) |
m/s |
2 | ||
|
m |
kg |
0.044 | 0.146 | 0.29 |
|
Operating conditions |
||||
|
Size |
15 | 22 | 30 | |
|
Admissible operating temperature (min ... max) 2) |
-30 °C ... +100 °C | |||
| 1) | In case of prolonged periods of use at speeds above 1 m/s, an increase in temperature and reduction in service life needs to be reckoned with depending on the load. |
| 2) | At temperatures above 100 °C, only bright metal load balls without a felt seal should be used. Make allowance for reduction in load capacity. Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out. |
At temperatures above 100 °C, only bright metal ball transfer units without a felt seal should be used. Note the reduction in load capacity! Use high-temperature lubricant! Follow the manufacturer’s instructions! The existing lubricant oil may have to be washed out.
Temperature factor
|
Temperature (°C) |
Temperature factor ft |
|
125 |
0,9 |
|
150 |
0,8 |
|
175 |
0,7 |
|
200 |
0,5 |
The load capacity must be multiplied by the temperature factor.
Legend
|
Symbol |
Description |
Unit |
Picture |
|
C |
Dynamic load capacity |
N |
|
|
C0 |
Static load capacity |
N |
|
|
vmax |
Conveying speed |
m/s |
|
|
m |
Mass |
kg |
Technical data
Applications
General-purpose machines Feed tables for sheet-metal working machines Fixtures for press brakes Feed devices for machining centers Drilling tables and motor-driven supporting tables Assembly aids in the manufacture of large engines and motors Construction of special-purpose machines Aerospace industry Beverages and stone-processing industries Not suitable for use under water
Conveyor systems
Ball transfer tables, turntables and switches for sorting and distribution systems Crossover sections of continuous conveyors Baggage sorting systems at airports Transport of steel tubes and pipes Lifting platforms
Dimensions
|
Size |
dw |
D |
Tolerance for D |
D1 |
h |
Tolerance for h |
H |
b |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
| 15 | 15.875 | 24 | - 0.13 | 31 | 9.5 | ± 0.2 | 20 | 5.5 |
| 22 | 22.225 | 36 | - 0.16 | 45 | 9.8 | 28.6 | 6.2 | |
| 30 | 30.162 | 45 | - 0.25 | 55 | 13.8 | ± 0.3 | 37.2 | 8.2 |
Installation dimensions
|
Size |
DB |
Tolerance for DB |
s |
|
mm |
mm |
mm |
|
| 15 | 24 | + 0.5 | 1.5 |
| 22 | 36 | + 0.8 | 2 |
| 30 | 45 | + 1 | 2.5 |