BOSCH REXROTH
R15612A007
$3,172.88 USD
- BOSCH REXROTH
- Material:R15612A007
- Model:MEASURING ROD EMC40
Quantity in stock: 0
The Bosch Rexroth MEASURING ROD (R15612A007) is a force sensor designed to provide precise load sensing in a variety of applications. This corrosion-resistant stainless steel sensor is easy to mount and is suitable for both dynamic and static measurements. It boasts high shock and vibration resistance, ensuring robust performance and long-term stability thanks to the thin-film technology used in its construction. The MEASURING ROD EMC40 has an operating temperature range from -°C to °C with a compensated temperature range specified by the manufacturer. The product features a Polyurethane (PUR) black, shielded cable with specific cable cross-section and bending radius requirements for both static (x D) and dynamic (x D) applications. It maintains a bandwidth with tolerance, indicating its responsiveness within the kHz range. For electrical connections, it utilizes a female connector Mx type with pin configuration ensuring secure connectivity. Its protection class is IP, safeguarding against ingress of dust and moisture under certain conditions. The output signal provided by this device ranges from V to V with specified tolerances, nonlinearity, hysteresis, and temperature drifts across both zero point and measuring range per Kelvin. The MEASURING ROD EMC40 also includes options for load measuring pin or clevis mount with force measuring bolts for versatile mounting possibilities. These features allow for accurate tension and compression force measurements within its specified operating load of the measuring range. With nominal sizes available, this product group ID size b offers flexibility for integration into various systems requiring precise force measurement solutions. The device's weight is . kg providing an indication of its heft relative to its size L dimensions. Overall, the Bosch Rexroth MEASURING ROD EMC40 is engineered for applications that demand accurate load detection with high reliability and minimal signal deviation under challenging environmental conditions.
Force sensors for EMC
Unpacked Weight: 0.506 kg
| 1) | Load measuring pin |
| 2) | Clevis mount with force measuring bolts |
If your application requires precise load sensing, there is a clevis bearing block version with force measuring bolt available for this purpose. This option can be selected on the end of the piston rod as well as on the timing belt side drive.
Thanks to the thin-film technology used, the load cells are very robust and stable over the long term. The load cells are compliant with the EN 61326 standard for electromagnetic compatibility (EMC) and are designed to sense both tensile and compressive forces.
| Data Sheet | Download Data Sheet |
| 3D CAD | Download 3D CAD |
| 3D CAD | Download 3D CAD |
| Manual | Download Manual |
| Manual | Download Manual |
| Manual | Download Manual |
| Cable diameter D tolerance | |
| Cable diameter D | 5.9 |
| Size a f8 | 12 |
| Product information | with connection cable |
| Maximum operating temperature | |
| Permissible ambient temperature | -25 °C ... +80 °C |
| Minimum operating temperature | |
| Size E | 28 |
| Connection type 2 | Flying leads |
| Electrical accessories for electromechanical cylinders | Force sensors |
| Type of cable | PUR black, shielded |
| Cable cross-section | 4x0,34 |
| Static bending radius | >10 x D |
| Dynamic bending radius | >5 x D |
| Operating temperature | -20 °C ... +60 °C |
| Power supply voltage | 24 |
| Suitable for drag chains | ja |
| Power supply voltage tolerance | |
| Max. zero setting function (tare) | 24 |
| Repeatability (of the measuring range) | |
| Max. ambient temperature, in motion | |
| Min. zero setting function (tare) | 7.2 |
| Output signal (measuring range) tolerance | |
| Measurement range | 5 |
| Rated voltage | 250 |
| Size c | 49.5 |
| Rated current | 4 |
| Temperature drift zero point (of the measuring range per Kelvin) | |
| Temperature drift above measuring range (of the measuring range per Kelvin) | |
| Compensated temperature max | |
| Compensated temperature min | |
| Productgroup ID | 17 |
| Size b | 89 |
| Measurement inaccuracy | |
| Permissible ambient temperature (max) | |
| Size d | 35 |
| Permissible ambient temperature (min) | |
| Bandwidth with tolerance | 2,5 kHz ±0,2 |
| Bandwidth tolerance | |
| Bandwidth | 2.5 |
| Connection | Connector M12x1 |
| Connection type 1 | Female connector, M12, 4-pin |
| Protection class | IP65 |
| Output signal with tolerance | 0 V ±0,03 |
| Hardness | 38 HRC |
| Operating load (of the measuring range) | 150 |
| Output signal | 0 |
| Breaking load (of the measuring range) | 300 |
| Output signal tolerance | |
| Non-linearity (of the measuring range) | |
| Output signal (measuring range) with tolerance | -10 ... +10 V ±0,2 |
| Hysteresis (of the measuring range) | |
| Output signal (measuring range) min | |
| Output signal (measuring range) max | |
| Size L | 5 |
| Supply voltage (min. … max.) | ± 2 V |
| Ambient temperature, in motion | |
| Weight | 0.506 |
| Zero setting function (tare) | 7.2 V ... 24 V |
| Connector outlet | angled |
| Nominal size | 40 |
Metrological specifications
|
EMC |
32 | 40 | 50 | 63 | 80 | 100 | 100XC | |
|
Measuring range |
kN |
1.3 | 5 | 8 | 16 | 22 | 45 | 56 |
|
Measurement inaccuracy |
kN |
± 0.007 | ± 0.025 | ± 0.04 | ± 0.08 | ± 0.11 | ± 0.23 | ± 0.28 |
|
Protection type |
IP65 | |||||||
|
Hardness (load sensing range) |
38 HRC | |||||||
|
Operating load (of the measuring range) |
% |
150 | ||||||
|
Breaking load (of the measuring range) |
% |
300 | ||||||
|
Non-linearity (of the measuring range) |
% |
± 0.5 | ||||||
|
Repeatability (of the measuring range) |
% |
± 0.25 | ||||||
|
Hysteresis (of the measuring range) |
% |
± 0.2 | ||||||
|
Temperature drift zero point (of the measuring range per Kelvin) |
% |
± 0.05 | ||||||
|
Temperature drift above measuring range (of the measuring range per Kelvin) |
% |
± 0.05 | ||||||
|
Compensated temperature (min ... max) |
+10 °C ... +40 °C | |||||||
|
Operating temperature (min ... max) |
-20 °C ... +60 °C | |||||||
Electrical specifications
|
Output signal (0kN) |
0 V ±0.03 |
|
Output signal (measuring range) |
-10 ... +10 V ±0.2 |
|
Power supply |
24 V ±2 |
|
Current consumption |
25 mA (24 V) |
|
Bandwidth |
2.5 kHz ±0.2 |
|
Tare (zero setting function) (min ... max) |
7.2 ... 24 V |
|
Connection |
Plug M12x1 |
Output signal 4 – 20 mA, reduced measurement range and test certificate on request.
Technische Daten Anschlusskabel
|
Length |
m |
5 |
|
Rated voltage |
V |
250 |
|
Rated current |
A |
4 |
|
Plug outlet |
Angled | |
|
1. connection type |
Female connector, M12, 4-pin | |
|
2. connection type |
Flying leads | |
|
Type of cable |
PUR black, shielded | |
|
Suitable for flexing installation |
yes | |
|
Cable cross-section |
mm2 |
4x0,34 |
|
Cable diameter D |
5.9 mm ±0.2 | |
|
Bending radius, stationary |
>10 x D | |
|
Bending radius, flexing |
>5 x D | |
|
Bending cycles |
> 2 million | |
|
Ambient temperature, fixed (min ... max) |
-25 °C ... +80 °C | |
|
Ambient temperature, in motion (min ... max) |
-40 °C ... +80 °C |
| Connection cable included in delivery |
Connection diagram
Connection diagram for load measuring pin
Force measuring bolt
1 Supply (+)
2 Tare
3 GND
4 Output
5 Internal allocation
Connection cable
1 brn = brown, power supply (+)
2 wht = white, tare
3 blu = blue, GND
4 blk = black, output
Output signal depending on load direction
Dimensions
|
EMC |
32 | 40 | 50 | 63 | 80 | 100 | 100XC | ||
|
⌀a |
f8 |
mm |
10 | 12 | 16 | 20 | 35 | ||
|
b |
mm |
83 | 89 | 99 | 107 | 109 | 119 | 170 | |
|
c |
mm |
43.5 | 49.5 | 58 | 66 | 67.5 | 77.5 | 124.5 | |
|
d |
mm |
35 | |||||||
|
⌀e |
mm |
28 | 35 | ||||||
Note
The use of a hammer or press to fit the pivot pin is not permitted.
It may only be inserted by hand.
The pivot pin is not suitable to handling torque. It is secured axially and against rotation, like the standard pin, on one side of the clevis mount using the included retaining ring and clamping pin.
For force control at the controller level, a control component with an analog input is required.