You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901425454


$899.00
  • BOSCH REXROTH
  • Material:R901425454
  • Model:HEDE10-3X/400/2/-GI-K35-0

Due to extremely high demand, please call 800-887-4183 for availability



Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Display for pressure values and parameters. Additional transmission of pressure and diagnosis values via IO-Link. All components in contact with the media are made of stainless steel. Excellent overload and bursting behavior.

Unpacked Weight: 0.240 kg
Thin film measuring cell
2 switching outputs
Parameterization via IO-Link or buttons at the device
Hydraulic connection G1/4
Throttle in pressure channel
Configuration via IO-Link or button at device
Throttle element in the pressure channel
Connector 4-pole, M12x1, A-coded
Maximum operating pressure 600 bar
Component series 3X
Pressure ratings 100, 250, 400 and 600 bar
Max. pressure400
Electrical connection descriptionConnector, 4-pole, M12 x 1, coding A according to EN 61076-2-101
Productgroup ID9,10,11,12,13,14
Conformity descriptionCE – electro-magnetic compatibility 2014/30/EU
RoHS Directive 2011/65/EU
Displayyes
Connection diagramInternal thread G1/4
Supply voltage24 VDC
Weight0.240
SealsFKM
Output signal2 switching outputs
Hydraulic fluidHL,HLP,HFC,HETG,HEES,HFD
ConformityCE,UL,UKCA,EAC,RoHS

01

02

03

04

05

06

07

08

HEDE10

-

3X

/

/

/-

-

-

-

*

01

Hydro-electric pressure switch

HEDE10

02

Component series 30 ... 39 (30 ... 39: unchanged installation and connection dimensions)

3X

03

Pressure rating maximum 100 bar

100 bar

Pressure rating maximum 250 bar

250 bar

Pressure rating maximum 400 bar

400 bar

Pressure rating maximum 600 bar

600 bar

Output

04

1 switching and 1 analog output

1

2 switching outputs

2

Hydraulic connection

05

Internal thread G1/4

Gi

Male thread G1/4

Ga

Electrical connection

06

Individual connection

Without mating connector; connector M12 DIN EN 61076-2-101 without cable with M12 connector, A-coded

K35 1)

Seal material

07

FKM seals

2)

V

Without seal (with internal thread)

0

08

Further details in the plain text

*

1) Mating connectors, separate order, see "Accessories"
2) Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

Accessories

Mating connectors for the electrical connection see chapter Electrical connection. Mounting clamp and protective cap see chapter Accessories.

Type

Component series

3X

General

Weight

m

kg

0.26

Installation position

any

Ambient temperature range

ϑ

°C

-25 … +80

Storage temperature range

ϑ

°C

-40 … +100

Sine test according to DIN EN 60068-2-6:1996-05

10 ... 2000 Hz, max. 20 g, 10 double cycles

Transport shock according to DIN EN 60068-2-27:1995-03

Half-sine 50 g / 11 ms,
3 x in positive direction,
3 x negative direction (a total of 18 single shocks)

Noise test according to DIN EN 60068-2-64: 1995-08

20...2000 Hz, 10 gRMS, 24 h

Conformity

CE

DIN EN 60947-1: 2007 / A1: 2011 / A2: 2014
DIN EN 60947-5-1: 2004 / A1: 2009
DIN EN 61058-1: 2002 / A2: 2008
DIN EN 60529: 1991 / A2: 2013

UL

UL, 508 17th edition File No E223220 (up to 350 bar)

Protection class according to DIN EN 60529

IP 65 / IP 67 with mating connector mounted and fitted

Protection class according to EN 50178

III

Hydraulic

Pressure measuring ranges

pN

bar

100 250 400 600 100 250 400 600 100 250 400 600 100 250 400 600

Overload protection

pmax

bar

300 500 800 300 500 800 300 500 800 300 500 800

Bursting pressure

p

bar

400 1000 1600 2500 400 1000 1600 2500 400 1000 1600 2500 400 1000 1600 2500

Switching point

Setting range

bar

1 … 100 2 … 250 4 … 400 6 … 600 1 … 100 2 … 250 4 … 400 6 … 600 1 … 100 2 … 250 4 … 400 6 … 600 1 … 100 2 … 250 4 … 400 6 … 600

Reset range

bar

0.5 … 99.5 1 … 249 2 … 398 3 … 597 0.5 … 99.5 1 … 249 2 … 398 3 … 597 0.5 … 99.5 1 … 249 2 … 398 3 … 597 0.5 … 99.5 1 … 249 2 … 398 3 … 597

In steps of

bar

0.5 1 2 3 0.5 1 2 3 0.5 1 2 3 0.5 1 2 3

Druckflüssigkeit 1)

see table below

Hydraulic fluid temperature range

(at the working port of the pressure switch)

ϑ

°C

-25 … +80

Viscosity range

mm²/s

10 … 800

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c)

Class 20/18/15 1)

Materials in contact with the medium

V4A (1.4542), FKM (with male thread)

Pressure port

Internal thread "Gi"

G1/4

Male thread "Ga"

G1/4
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM, low-temperature seals

DIN 51524

90220

Bio-degradable

⇒Insoluble in water

HETG

NBR, FKM

ISO 15380

90221

HEES

FKM

⇒Soluble in water

HEPG

FKM

ISO 15380

Flame-resistant

⇒Water-free

HFDU, HFDR

FKM

ISO 12922

90222

⇒Containing water

HFC (Fuchs Hydrotherm 46M,

Petrofer Ultra Safe 620)

NBR

ISO 12922

90223

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids, please refer to the data sheets above or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature.

 

• Flame-resistant – containing water:

- Maximum pressure differential per control edge 50 bar

- Pressure pre-loading at the tank port >20% of the pressure differential, otherwise increased cavitation

- Life cycle as compared to operation with mineral oil HL, HLP 50 to 100%

 

• Bio-degradable and flame-resistant:

When using hydraulic fluids that are simultaneously zinc-solving, zinc may accumulate (700 mg zinc per pole tube).

Electric

Electrical connection

M12 plug-in connection, gold-plated contacts

Input variables

Operating voltage

UB

18 … 30 VDC

Current consumption

I

mA

< 50

Isolation resistance

>100 (500 VDC)

Output parameters

Analog output

Current carrying capacity

U

0 ... 10 VDC (minimum load 2000 Ω)

Voltage

I

4 ... 20 mA (max. load (UB – 10) x 50 Ω)

Rise time (10 to 90 %)

t

ms

3

Switching output

Output function

Normally open contact / normally closed contact programmable

Current carrying capacity 1)

I

mA

150

Voltage drop (short-circuit protection clocked)

U

V

< 2.5

Overload-resistant

yes

Switching frequency

f

Hz

≤ 170

Accuracy / variations

Characteristic curve deviation 2)

%

< ± 0.5

Temperature coefficient

Zero point and range

< 0.2 % / 10 K

Hysteresis

%

< ± 0.25

Switching point accuracy

%

< ± 0.5

Repetition accuracy

%

0.1

Programming options

Hysteresis/window; normally open contact/normally closed contact; activation, deactivation delay; damping; indicator unit/diagnosis output

Long-term drift under reference conditions (6 months)

%

0.05

EMC (electro-magnetic compatibility)

EN 61000-4-2 ESD

kV

4 / 8

EN 61000-4-3 HF radiated

V/m

10

EN 61000-4-4 Burst

kV

2

EN 61000-4-5 Surge

kV

1

EN 61000-4-6 HF conducted

V

10

Reaction times

Readiness delay time

s

0.3

Minimal reaction time switching output

ms

<3

Adjustable delay time dS, dr

s

0...50

Damping switching output (dAP)

s

0...4

Damping analog output (dAA)

s

0...4

Rise time analog output

ms

< 3

Watchdog integrated

yes

Switching cycles min.

100 million / 50 million with pressure rating 600 bar

IO-Link device

Transmission type

COM2 (38.4 kBaud)

IO-Link revision

1.1

SDCI standard

IEC 61131-9

Profiles

Smart Sensor: Process Data Variable;
Device Identification, Device Diagnosis

SIO mode

yes

Required master port class

A

Process data analog

1

Process data binary

2

Minimal process cycle time

ms

2.3

Display

Indicator unit

3 x LED green (bar, psi, MPa)

Switching status

2 x LED yellow

Measured values

4-digit alphanumerical display / alternating display (red and green)
1) 200 (...60 °C); 250 (...40 °C) mA
2) according to end point setting DIN16086

For applications outside these parameters, please consult us!

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

1 ... 8: indicator LEDs

LED 1

Switching status OUT1 (is illuminated when output 1 is switched through)

LED 8

Switching status OUT2 (is illuminated when output 2 is switched through)

LED 2 ... 7 1)

System pressure in the specified unit of measurement

9: Enter key [•]

Selection of the parameters and confirmation of the parameter values

10 and 11: Arrows up [⇑] and down [⇓]

Setting of the parameter values (permanent by continuous pressure; step-wise by pressing individually)

12: Alphanumerical display, 4-digit

Display of the current system pressure

Display of the parameters and parameter values

1) With variant 1 switching and 1 analog output, these LEDs don’t have any function.

according to DIN EN 175301-803

"K35" two switching outputs

n-switching (NPN)

p-switching (PNP)

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

OUT1: Switching output or IO-Link
OUT2: Switching output
Color marking according to DIN EN 60947-5-2

OUT1: Switching output or IO-Link
OUT2: Switching output
Color marking according to DIN EN 60947-5-2

"K35" one switching and one analog output:

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

OUT1: Switching output or IO-Link
OUT2: 4 ... 20 mA / 0 ... 10 V
Color marking according to DIN EN 60947-5-2

Connector view at the device:

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

When establishing the electrical connection, the protective earthing conductor (PE, grounded) must be connected correctly.

Dimensions in mm

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element
1) Depending on lubrication, seal and pressurization

1​

Status LEDs

2

4-digit alphanumerical display

3

Programming button

4

Dimension for "Gi" version with internal thread G1/4"

5

Dimension for "Ga" version with male thread G1/4"

Notice:

Oscillation-free installation is recommended.

Mounting clamp for HEDE 10

Designation

Material number

Buy

Fastening clamp E10193 R900786138 eShop
technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Protective cap for HEDE 10

Designation

Material number

Buy

Protective cap HEDE10-3X R901453193 eShop
Show all products technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2

Data sheet

Spare parts & repair

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line

4P Z24 +

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line

4P Z24 +

For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2

Data sheet

Spare parts & repair

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded

4P M12 +

technical illustration-R901425454-Electronic pressure switch with display, 2 switching outputs, pressure range 0 … 400 bar, connector 4-pole M12x1 A-coded, throttle element

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded

4P M12 +

For sensors and valves with connector “K24”, “K35” and “K72” Cable sets M12, 4-pole, line cross-section 0.34 mm2

Data sheet

Spare parts & repair