Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

SUN HYDRAULICS CORP
HDDADCN912N
Solenoid Operated

Cartridge

$185.70

SUN HYDRAULICS CORP

MATERIAL:  HDDADCN912N

SUMMARY:  Cartridge

Add to Cart

This solenoid-after check cartridge is a hybrid valve incorporating a direct acting solenoid poppet valve teed in after the check function. The check valve flow is from the inlet (port 2) to the system (port 1). With the solenoid de-energized flow from (port 2) to (port 3) is blocked. This combination valve is typically used in lift/lower applications and can be integrated directly into the actuator.

  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assembly has a mechanical life expectancy of approximately 7,000 cycles.
  • This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is not compatible with weatherized coils.
  • Suitable for load holding applications.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details. Additional weatherized coils and kits are available for more complete environmental protection.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 10 gpm40 L/min.
Maximum Operating Pressure 5000 psi350 bar
Response Time - Typical 50 ms50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 10 drops/min.@5000 psi0,7 cc/min.@350 bar
Check Cracking Pressure 30 psi2 bar
Switching Frequency 15000 cycles/hr15000 cycles/hr
Manual Override Force Requirement 5 lbs/1000 psi @ Port 133 N/100 bar @ Port 1
Manual Override Stroke .10 in.2,5 mm
Solenoid Tube Diameter .75 in.19 mm
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Seal kit - Cartridge Viton: 990-011-006
Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006

Show FAQ