Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
3842998529
All Other Products

Modules TS5: diverter

BOSCH REXROTH

MATERIAL:  3842998529

SUMMARY:  Modules TS5: diverter

Due to extremely high demand, please call 888-651-5712 for availability

With the illustrated gravity center position transport problems may occur at the transition from the secondary section to the main section.

Limits for the permissible gravity center position for junctions and diverters

technical illustration-3842998529-Modules TS5: diverter

Set up of curves, diverters, junctions

technical illustration-3842998529-Modules TS5: diverter
1) Outlet
2) Inlet
3) Transport height difference between main and secondary section
technical illustration-3842998529-Modules TS5: divertertechnical illustration-3842998529-Modules TS5: diverter

S1

=

WT after VE (Z1)

S3

=

WT behind main section diverter

S4

=

WT behind secondary section diverter

S5

=

Diverter open

S6

=

Diverter closed

Y2

=

Diverter (Z2)

Y1

=

Stop gate (Z1)

A1

=

Identification system with straight-ahead signal

technical illustration-3842998529-Modules TS5: diverter

DI 5/H, DI 5/XH diverters

technical illustration-3842998529-Modules TS5: diverter

b1) (mm)

lWT2) (mm)

N

l13) (mm)

l24) (mm)

l35) (mm)

l4 (mm)

455

455; 650

13

1300

382,5

650

917,5

650

650; 845

15

1560

415

780

1145

845

845; 1040

17

1820

447

910

1372,5

1) b = track width in direction of transport
2) lWT = workpiece pallet length (in direction of transport)
3) l1 = length of the main section
4) l2 = length of the secondary section
5) l3 = length of secondary section up to center of main section

Permissible gravity center position

In order to absorb acceleration forces without any problems when separating and changing the direction of the pallets (in curves, when changing to transverse conveyors), the location of the load center position on the workpiece pallet must be noted.

 

Generally we recommend that:

the load should be positioned in the center of the workpiece pallet the load center positionS should not exceed 1/3 bWT (with bWT ≤ lWT) in height technical illustration-3842998529-Modules TS5: diverter

Condition of Delivery

DI 5/XH diverter Ready-to-install Optional: Protective covers mounted (protective covers cannot be ordered separately)
DI 5/H diverter