Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
R074022530
All Other Products

LB Standard- 25-Flange -NR

$326.40

BOSCH REXROTH

MATERIAL:  R074022530

SUMMARY:  LB Standard- 25-Flange -NR

Add to Cart

General technical data

Ø d

mm

5 8 12 16 20 25 30 40

amax

m/s²

100

vmax

m/s

2.5

m

kg

0.02 0.033 0.064 0.09 0.15 0.3 0.47 0.98

FR 1)

N

0.4 0.5 2 3 4 5 6 8

Breakaway force

N

0.8 1 6 9 12 14 18 24

Rows of balls

4 5 6

Working bore diameter tolerance

µm

+ 8
0
+ 9
- 1
+ 11
- 1
+ 13
- 2

Shaft radial clearance h6 2)

µm

+ 14
+ 2
+ 15
+ 2
+ 16
+ 3
+ 17
+ 2
+ 19
+ 2
+ 20
+ 3
+ 24
+ 3

Operating conditions

Permissible ambient temperature (min ... max) 3)

-10 °C ... +80 °C
1) Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication.
2) Determined from working bore diameter and shaft tolerance statistics. Recommended housing bore tolerance: H6 or H7.
3) Only unsealed Linear Bushings with steel ball retainers may be used at higher temperatures. Make allowance for reductions in load capacity.

Load capacities and load moments

Ød

mm

5 8 12 16 20 25 30 40

Cmin

N

160 210 400 460 680 780 1250 1720

Cmax

N

185 240 460 530 800 830 1320 1820

C0min

N

180 235 420 440 860 1620 2000 3300

C0max

N

250 330 600 630 1250 2100 2500 4200
The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the  values in the table need to be multiplied by 1.26.

Legend

Symbol

Description

Unit

Ød

Shaft diameters

mm

amax

Maximum acceleration travel

m/s2

Cmax

Maximum dynamic load rating

N

Cmin

Minimum dynamic load rating

N

C0max

Maximum static load rating

N

C0min

Minimum static load rating

N

FR

Friction force

N

m

Mass

kg

vmax

Maximum permissible speed

m/s

Impact of load direction on load rating of closed Linear Bushings

The listed load ratings should be chosen depending on installation in minimum or maximum position and should be based on the calculations. If the load direction is clearly defined and the Linear Bushings can be installed in maximum position, the load ratings Cmax. (dynamic load rating) and C0 max (static load rating) can be used. If aligned installation is not possible or the load direction is not defined, the minimum load ratings must be used.

 

technical illustration-R074022530-LB Standard- 25-Flange         -NR

Definition of dynamic load ratings

Installation dimensions/interchangeability

Standard Linear Bushings have the same installation dimensions as super Linear Bushings. They are interchangeable, differ however in terms of securing, radial clearance, load ratings and lubrication.

Sealing

Standard Linear Bushings come with a wiper seal with shaft diameters of 5 and higher. Open standard Linear Bushings with shaft diameters 20 to 80 can also come fully sealed (with longitudinal seal; increased friction).

technical illustration-R074022530-LB Standard- 25-Flange         -NR

Dimensions

Ød

mm

5 8 12 16 20 25 30 40

B

mm

22 25 32 35 42 50 60 75

D

12 mm -0.013 16 mm -0.013 22 mm -0.016 26 mm -0.016 32 mm -0.019 40 mm -0.019 47 mm -0.019 62 mm -0.022

D1

mm

28 32 42 46 54 62 76 98

D2

mm

20 24 32 36 43 51 62 80

L

22 mm ±0.3 25 mm ±0.3 32 mm ±0.3 36 mm ±0.3 45 mm ±0.3 58 mm ±0.3 68 mm ±0.3 80 mm ±0.3

L1

mm

5 6 8 10 13

L1

5 mm 6 mm 8 mm 10 mm 13 mm

S

mm

3.5 4.5 5.5 6.6 9

V

mm

3.1 4.1 5.1 6.1 8.1

Life expectancy calculation

General mounting instructions

Customer-built housings

Initial lubrication

Linear bushings do not come with initial lubrication. Grease the Linear Bushings before use. Service life data is based on initial lubrication and relubricated Linear Bushings.

technical illustration-R074022530-LB Standard- 25-Flange         -NR

Lubrication

Directives and standards

Notes