Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
VT-DFP-A-2X/G24K0/0/V
R900703811
Proportional Directional Valves

VT-DFP.-2X

$3,063.00

BOSCH REXROTH

MATERIAL:  R900703811

SUMMARY:  VT-DFP.-2X

Add to Cart

01

02

03

04

05

06

07

08

09

10

11

VT-DFP

-

-

2X

/

G24

K0

/

/

-

*

Series

01

Pilot valve for external electronics

VT-DFP

Spool design

02

Standard (not for HFC fluids)

A

2-groove spool (only for replacement requirement)

B

4-groove spool (e.g. for HFC fluids)

C

03

Component series

2X

04

Direct voltage 24 V

G24

05

Connector (without mating connector) 1)

K0

Installation orientation connector (VT-DFP) and/or integrated electronics (see also comment on feature 6)

06

radially to the pump axis

0

folded 90° in the direction of the subplate with counterclockwise direction of rotation

1

folded 90° in the direction of the subplate with clockwise direction of rotation

2

Additional functions: Closed-loop control

A

B

C

D

R

07

(without)

Electronics assembly, option

08

(without)

Actual pressure value input
(For the description of the connectors refer to electrical connection)

Plug-in connector

09

(without)

10

FKM seals suitable for mineral oils (HL, HLP) according to DIN 51524 and HFC fluids 2)

V

11

Further details in the plain text e. g. SO variant

*

1

Material number

2

Serial number

3

Date of production

4

Production order number

5

Type designation

available

-

not available

Note on feature 6: Installation orientation of the valve electronics

Clockwise direction of rotation, installation orientation 0

Clockwise direction of rotation, installation orientation 2

Counterclockwise direction of rotation, installation orientation 0

Counterclockwise direction of rotation, installation orientation 1

technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X
1) Connector dependent on the valve type (see "Technical data" and "Electrical connection”).
2) With the SY(H)DFEn control system with analog interfaces, the plug-in connector X2 can not be used as actual pressure value input. Thus, a separate pressure transducer has to be used and connected to plug-in connector X1 in this case.
3) Only in connection with SYHDFE and spool design C (feature 2).
technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X

1

Material number

2

Serial number

3

Date of production

4

Production order number

5

Type designation

available

-

not available

Accessories

Version 10/2011, enquire availability

Notice:

For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.

mechanic and hydraulic

Mass

Pump without through-drive incl. pilot valve

m

kg

1.96

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

mechanic and hydraulic

Weight without filling quantity

m

kg

1.96

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

electrical

Operating voltage

UB

see VT5041-3X

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

see VT5041-3X

Analog current inputs, load

RB

see VT5041-3X

Analog voltage inputs

RE

see VT5041-3X

Digital inputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Outputs

pactual / UOUT1

UO

see VT5041-3X

Imax

see VT5041-3X

αactual / UOUT2

UO

see VT5041-3X

Imax

see VT5041-3X

Digital outputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Ambient temperature range at the pump

ϑ

°C

-20 … +60

Storage temperature range (pump + electronics)

ϑ

°C

-20 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

mechanisch und hydraulisch

Weight without filling quantity

m

kg

1.96

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

elektrisch

Operating voltage

UB

see VT5041-3X

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

see VT5041-3X

Analog current inputs, load

RB

see VT5041-3X

Analog voltage inputs

RE

see VT5041-3X

Digital inputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Outputs

nactual / UOUT1

UO

see VT5041-3X

Imax

see VT5041-3X

αactual / UOUT2

UO

see VT5041-3X

Imax

see VT5041-3X

Digital outputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Ambient temperature range at the pump

ϑ

°C

-20 … +60

Storage temperature range (pump + electronics)

ϑ

°C

-20 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

elektrisch

Operating voltage

UB

see VT5041-3X

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

see VT5041-3X

Analog current inputs, load

RB

see VT5041-3X

Analog voltage inputs

RE

see VT5041-3X

Digital inputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Outputs

pactual / UOUT1

UO

see VT5041-3X

Imax

see VT5041-3X

αactual / UOUT2

UO

see VT5041-3X

Imax

see VT5041-3X

Digital outputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Ambient temperature range at the pump

ϑ

°C

-20 … +60

Storage temperature range (pump + electronics)

ϑ

°C

-20 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

mechanisch und hydraulisch

Mass

Pump without through-drive incl. pilot valve

m

kg

1.96

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code)

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

Class 18/16/13 (for particle size ≤ 4/6/14 μm)

elektrisch

Operating voltage

UB

see VT5041-3X

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

see VT5041-3X

Analog current inputs, load

RB

see VT5041-3X

Analog voltage inputs

RE

see VT5041-3X

Digital inputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Outputs

pactual / UOUT1

UO

see VT5041-3X

Imax

see VT5041-3X

αactual / UOUT2

UO

see VT5041-3X

Imax

see VT5041-3X

Digital outputs

Logic 0

see VT5041-3X

Logic 1

see VT5041-3X

Ambient temperature range at the pump

ϑ

°C

-20 … +60

Storage temperature range (pump + electronics)

ϑ

°C

-20 … +70

Type of protection according to EN 60529

Pump incl. pilot valve

IP65 with mounted and locked plug-in connectors

For applications outside these parameters, please consult us!

For external analog electronics

Details on the electrical connection to the VT 5041-3X amplifier are described in data sheet 30242.

Solenoid

Mating connector 3-pole Z4 M SW according to DIN EN 175301-803 (separate order see Accessories)

Mating connector 4-pole Pg7-G4W1F/Pg7 SW (separate order see Accessories)

Dimensions in mm

technical illustration-VT-DFP-A-2X/G24K0/0/V-VT-DFP.-2X

Valve mounting screws for all types:

4 hexagon socket head cap screws

ISO4762-M6X40-10.9-flZn-240h-L,

friction coefficient μtotal = 0.09 to 0.14 according to VDA 235-101,

Tightening torque MA = 7 Nm,

material number: R913000058

Amending notes on the SY(H)DFE control systems can be found in the operating instructions (see section “Further information about this control system”).