BOSCH REXROTH
VT-DFP-A-2X/G24K0/0/V
R900703811
Proportional Directional Valves
VT-DFP.-2X
BOSCH REXROTH
MATERIAL: R900703811
SUMMARY: VT-DFP.-2X
Quantity in stock: 0
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
11 |
||||||
VT-DFP |
- |
- |
2X |
/ |
G24 |
K0 |
/ |
/ |
- |
* |
Series |
|||||||
01 |
Pilot valve for external electronics |
VT-DFP |
|||||
Spool design |
|||||||
02 |
Standard (not for HFC fluids) |
A |
|||||
2-groove spool (only for replacement requirement) |
B |
||||||
4-groove spool (e.g. for HFC fluids) |
C |
||||||
03 |
Component series |
2X |
|||||
04 |
Direct voltage 24 V |
G24 |
|||||
05 |
Connector (without mating connector) 1) |
K0 |
|||||
Installation orientation connector (VT-DFP) and/or integrated electronics (see also comment on feature 6) |
|||||||
06 |
radially to the pump axis |
0 |
|||||
folded 90° in the direction of the subplate with counterclockwise direction of rotation |
1 |
||||||
folded 90° in the direction of the subplate with clockwise direction of rotation |
2 |
||||||
Additional functions: Closed-loop control |
A |
B |
C |
D |
R |
||
07 |
(without) |
||||||
Electronics assembly, option |
|||||||
08 |
(without) |
||||||
Actual pressure value input |
Plug-in connector |
||||||
09 |
(without) |
||||||
10 |
FKM seals suitable for mineral oils (HL, HLP) according to DIN 51524 and HFC fluids 2) |
V |
|||||
11 |
Further details in the plain text e. g. SO variant |
* |
1 |
Material number |
2 |
Serial number |
3 |
Date of production |
4 |
Production order number |
5 |
Type designation |
● |
available |
- |
not available |
Note on feature 6: Installation orientation of the valve electronics
Clockwise direction of rotation, installation orientation 0 |
Clockwise direction of rotation, installation orientation 2 |
Counterclockwise direction of rotation, installation orientation 0 |
Counterclockwise direction of rotation, installation orientation 1 |
1) | Connector dependent on the valve type (see "Technical data" and "Electrical connection”). |
2) | With the SY(H)DFEn control system with analog interfaces, the plug-in connector X2 can not be used as actual pressure value input. Thus, a separate pressure transducer has to be used and connected to plug-in connector X1 in this case. |
3) | Only in connection with SYHDFE and spool design C (feature 2). |
1 |
Material number |
2 |
Serial number |
3 |
Date of production |
4 |
Production order number |
5 |
Type designation |
● |
available |
- |
not available |
Accessories
Version 10/2011, enquire availability
Notice:
For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.
mechanic and hydraulic
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
1.96 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
mechanic and hydraulic
Weight without filling quantity |
m |
kg |
1.96 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
electrical
Operating voltage |
UB |
see VT5041-3X | ||
Inputs |
Actual pressure value input X1; |
U or I |
see VT5041-3X | |
Analog current inputs, load |
RB |
see VT5041-3X | ||
Analog voltage inputs |
RE |
see VT5041-3X | ||
Digital inputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Outputs |
pactual / UOUT1 |
UO |
see VT5041-3X | |
Imax |
see VT5041-3X | |||
αactual / UOUT2 |
UO |
see VT5041-3X | ||
Imax |
see VT5041-3X | |||
Digital outputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Ambient temperature range at the pump |
ϑ |
°C |
-20 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
-20 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
mechanisch und hydraulisch
Weight without filling quantity |
m |
kg |
1.96 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | ||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
elektrisch
Operating voltage |
UB |
see VT5041-3X | ||
Inputs |
Actual pressure value input X1; |
U or I |
see VT5041-3X | |
Analog current inputs, load |
RB |
see VT5041-3X | ||
Analog voltage inputs |
RE |
see VT5041-3X | ||
Digital inputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Outputs |
nactual / UOUT1 |
UO |
see VT5041-3X | |
Imax |
see VT5041-3X | |||
αactual / UOUT2 |
UO |
see VT5041-3X | ||
Imax |
see VT5041-3X | |||
Digital outputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Ambient temperature range at the pump |
ϑ |
°C |
-20 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
-20 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
elektrisch
Operating voltage |
UB |
see VT5041-3X | ||
Inputs |
Actual pressure value input X1; |
U or I |
see VT5041-3X | |
Analog current inputs, load |
RB |
see VT5041-3X | ||
Analog voltage inputs |
RE |
see VT5041-3X | ||
Digital inputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Outputs |
pactual / UOUT1 |
UO |
see VT5041-3X | |
Imax |
see VT5041-3X | |||
αactual / UOUT2 |
UO |
see VT5041-3X | ||
Imax |
see VT5041-3X | |||
Digital outputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Ambient temperature range at the pump |
ϑ |
°C |
-20 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
-20 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
mechanisch und hydraulisch
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
1.96 |
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; HFC fluids only in connection with SYHDFE control system and C spool design C (feature 2 of ordering code) | |||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
elektrisch
Operating voltage |
UB |
see VT5041-3X | ||
Inputs |
Actual pressure value input X1; |
U or I |
see VT5041-3X | |
Analog current inputs, load |
RB |
see VT5041-3X | ||
Analog voltage inputs |
RE |
see VT5041-3X | ||
Digital inputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Outputs |
pactual / UOUT1 |
UO |
see VT5041-3X | |
Imax |
see VT5041-3X | |||
αactual / UOUT2 |
UO |
see VT5041-3X | ||
Imax |
see VT5041-3X | |||
Digital outputs |
Logic 0 |
see VT5041-3X | ||
Logic 1 |
see VT5041-3X | |||
Ambient temperature range at the pump |
ϑ |
°C |
-20 … +60 | |
Storage temperature range (pump + electronics) |
ϑ |
°C |
-20 … +70 | |
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
For applications outside these parameters, please consult us!
For external analog electronics
Details on the electrical connection to the VT 5041-3X amplifier are described in data sheet 30242.
Solenoid
Mating connector 3-pole Z4 M SW according to DIN EN 175301-803 (separate order see Accessories)
Mating connector 4-pole Pg7-G4W1F/Pg7 SW (separate order see Accessories)
Dimensions in mm
Valve mounting screws for all types:
4 hexagon socket head cap screws
ISO4762-M6X40-10.9-flZn-240h-L,
friction coefficient μtotal = 0.09 to 0.14 according to VDA 235-101,
Tightening torque MA = 7 Nm,
material number: R913000058
Amending notes on the SY(H)DFE control systems can be found in the operating instructions (see section “Further information about this control system”).