Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
4WRE10EA75-2X/G24K4/V
R900969351
Proportional Directional Valves

Prop. dir. valves: WRE,WREE* 10.-2x/

$2,132.00

BOSCH REXROTH

MATERIAL:  R900969351

SUMMARY:  Prop. dir. valves: WRE,WREE* 10.-2x/

Add to Cart

Type 4WRE...-2X/...

The 4/2 and 4/3 proportional directional valves are designed as direct operated devices in plate design. Operation by means of proportional solenoids with central thread and detachable coil. The solenoids are controlled by external electronics.

Set-up:

The valve basically consists of:

Housing (1) with connection surface Control spool (2) with compression springs (3 and 4) and spring plates (5 and 6) Solenoids (7 and 8) with central thread Position transducer (9)

Function:

With de-energized solenoids (7 and 8), central position of the control spool (2) due to compression springs (3 and 4) between the spring plates (5 and 6) Direct actuation of the control spool (2) by the control of one proportional solenoid, e. g. solenoid "b" (8) Control spool (2) is moved to the left in proportion to the electrical input signal Connection from P to A and B to T via orifice-type cross-sections with progressive flow characteristics Switching off of the solenoid (8) Control spool (2) is returned to the central position by the compression spring (3)

In the de-energized state, the control spool (2) is held in a mechanical central position by the return spring of the solenoids. With control spool symbol "V", this position does not correspond to the hydraulic central position! When the electric valve control loop is closed, the control spool is positioned in the hydraulic central position.

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Important notice:

The PG fitting (11) must not be opened. Mechanical adjustment of the adjustment nut located below is prohibited and damages the valve!

Valve with two spool positions: (Type 4WRE…A...)

The function of this valve version basically corresponds to the valve with three spool positions. The 2 spool position valve is, however, only equipped with solenoid “a” (7). Instead of the 2nd proportional solenoid, a plug screw (10) is installed.

Notice:

Due to the design principle, internal leakage which may increase over the life cycle is inherent to the valves.

Notice:

The tank line must not be allowed to run empty. With corresponding installation conditions, a preload valve (preload pressure approx. 2 bar) must be installed.

01

02

03

04

05

06

07

08

09

10

4

WRE

2X

/

G24

K4

/

*

01

4 main ports

4

02

Proportional directional valve with electrical position feedback

WRE

03

Size 6

6

Size 10

10

04

Symbols; for the possible version, see "Symbols/Circuit diagrams"

E; E1-; V; V1-; W; W1-; EA; WA

Rated flow NG6

05

4 l/min

4

8 l/min

8

16 l/min

16

32 l/min

32

Rated flow NG10

05

25 l/min

25

50 l/min

50

75 l/min

75

06

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions)

2X

07

Supply voltage 24 V

G24

Electrical connection

08

Connector DIN EN 175301-803

K4

Seal material

09

NBR seals

M

FKM seals

V

10

Further details in the plain text

*

For applications outside these parameters, please consult us!

general

Type

4WRE

Size

6

Installation position

any, preferably horizontal

Ambient temperature range

°C

-20 … +70

Storage temperature range

°C

-20 … +80

Weight

kg

2.2

MTTFD values according to EN ISO 13849 1)

y

150
1) With control spool types E, E1, EA, W, W1, WA; in longitudinal control spool direction, there is sufficient positive overlap without shock/vibration load; observe the installation orientation with regard to the main direction of acceleration.

hydraulic

Size

6

Maximum operating pressure

bar

315

Maximum operating pressure

Port P

bar

315

Port T

bar

210

Port A

bar

315

Port B

bar

315

Maximum flow

l/min

80

Nominal flow

l/min

4
8
16
32

Hydraulic fluid

see table below

Hydraulic fluid temperature range

°C

-20 … +80

preferably

°C

+40 … +50

Viscosity range

mm²/s

20 … 380

preferably

mm²/s

30 … 46

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)

Class 20/18/15 according to ISO 4406 (c)

Hysteresis

%

≤ 0.1

Range of inversion

%

≤ 0.05

Response sensitivity

%

≤ 0.05

Zero shift upon change of

Hydraulic fluid temperature

%/10 K

≤ 0.15

Operating pressure

%/100 bar

≤ 0.1
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

Flame-resistant   - containing water

HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620)

NBR

ISO 12922

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant - containing water:
Maximum pressure differential per control edge 175 bar
Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %

electrical

Size

6

Voltage type

Direct voltage

Maximum current consumption

of the amplifier

A

2

of the amplifier (impulse current)

A

3

Solenoid coil resistance

Cold value at 20 °C

Ω

2.65

Maximum hot value

Ω

4.05

Actuated time

%

100

Maximum coil temperature 1)

°C

150

Protection class according to DIN EN 60529

IP65 (with mating connector mounted and locked)

Power supply

V

24

Supply voltage range

V

19.4 … 35
1) Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.

(measured with HLP46, ϑÖl = 40 ±5 °C)

Zero flow with central control spool position “V32”

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Rated flow 4 l/min at a valve pressure differential of 10 bar

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Rated flow 8 l/min at a valve pressure differential of 10 bar

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Rated flow 16 l/min at a valve pressure differential of 10 bar

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Rated flow 32 l/min at a valve pressure differential of 10 bar

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Load function with maximum valve opening;Rated flow 4, 8, 16 and 32 l/min;Control spool V

NG6

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Symbols

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

With symbol E1-, V1- and W1-, the following applies:

P → A: qvmax

B → T: qv/2

P → B: qv/2

A → T: qvmax

Notice:
In the zero position, control spool symbols W and WA have a connection from A → T and from B → T with approx. 3% of the relevant nominal cross-section.

Connection at connector

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Connection at mating connector

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Inductive position transducer

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

4WRE 6

Dimensions in mm

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

1

Valve housing

2

Proportional solenoid "a" with inductive position transducer

3

Proportional solenoid "b"

4

Mating connector "A", color gray, separate order

5

Mating connector "B", color black, separate order

6

Mating connector for inductive position transducer, separate order

7

Plug screw for valves with one solenoid (2 spool positions, version "EA" or "WA")

8

Identical seal rings for ports A, B, P, and T

9

Space required to remove the mating connector

10

Name plate

11

Machined valve contact surface; Porting pattern according to ISO 4401-03-02-0-05 (with locating hole)
Deviating from the standard:
- without locating hole "G"
- ports P, A, B and T with Ø8 mm

Recommended valve mounting screws (separate order):

4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L

tightening torque MA = 7 Nm ± 10%, material no. R913000064 or

4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9

tightening torque MA = 8.9 Nm ± 10%

1

Valve housing

2

Proportional solenoid "a" with inductive position transducer

3

Proportional solenoid "b"

4

Mating connector "A", color gray, separate order

5

Mating connector "B", color black, separate order

6

Mating connector for inductive position transducer, separate order

7

Plug screw for valves with one solenoid (2 spool positions, version "EA" or "WA")

8

Identical seal rings for ports A, B, P and T (T1)

9

Space required to remove the mating connector

10

Name plate

11

Machined valve contact surface; Porting pattern according to ISO 4401-05-04-0-05
Deviating from the standard:
Port T1 with Ø11.2 mm

Mating connectors for valves with connector “K4”, without circuitry, standard

3P Z4

technical illustration-4WRE10EA75-2X/G24K4/V-Prop. dir. valves: WRE,WREE* 10.-2x/

Mating connectors for valves with connector “K4”, without circuitry, standard

3P Z4

For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)

Data sheet

Spare parts & repair