Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
Z4WE6E137-3X/EG24N9K4
R900975026
Directional Spool Valves

Directional spool valves: Z4W* 6.-3x/

$709.00

BOSCH REXROTH

MATERIAL:  R900975026

SUMMARY:  Directional spool valves: Z4W* 6.-3x/

Add to Cart

Type Z4WE 6…

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

component side

plate side

01

02

03

05

07

08

09

10

11

12

13

14

Z4WE

6

3X

/

E

K4

*

01

Shut-off valve, sandwich plate

ZW4E

02

Size

6

Symbols

03

e.g. D24, E51, E53, ...; with DC or AC solenoids

e.g. X250, X252, ...; only with DC solenoids (AC voltage on request)

05

Component series 30 ... 39 (30 ... 39: unchanged installation and connection dimensions)

3X

07

High-power solenoid, wet-pin, with detachable coil

E

08

Direct voltage 24 V

G24

Alternating voltage 230 V, 50/60 Hz

W230

Direct voltage 205 V

G2051)

09

With concealed manual override (standard)

N9

With manual override

N

Without manual override

no code

Electrical connection

10

Without mating connector, with connector DIN EN 175301-803

K42)

Spool position monitoring

11

Without position switch

no code

Monitored spool position "a"

QMAG24

Monitored spool position "b"

QMBG24

Monitored rest position

QM0G24

Seal material

12

NBR seals

no code

FKM seals (other seals upon request)

V

Observe compatibility of seals with hydraulic fluid used.

13

no code

With locating hole

/603)

With locating hole and locking pin ISO 8752-3x8-St

/62

14

Further details in the plain text

*

Notice!

Inductive position switch type QM not available for symbol "E53“

AC voltage mains (admissible voltage tolerance ± 10%)

Nominal voltage of the DC solenoid in case of operation with alternating voltage

Ordering code

110 V - 50/60 Hz

96 V

G96

230 V - 50/60 Hz

205 V

G205

Preferred types and standard units are contained in the EPS (standard price list).

general

Size

6

Weight

Valve with one solenoid

kg

1.2

Valve with two solenoids

kg

1.6

Installation position

any

Ambient temperature ranges (NBR seals)

°C

-30 … +50

Ambient temperature ranges (FKM seals)

°C

-20 … +70

MTTFD values according to EN ISO 13849 1)

Years

150

Admissible shock and vibration loads

see data sheet 08012
1) For further details, see data sheet 08012

hydraulic

Size

6

Maximum operating pressure

Port P

bar

315

Anschluss A

bar

315

Port B

bar

315

Port T

with DC solenoid

bar

210

with AC solenoid

bar

160

Maximum flow

l/min

50

Hydraulic fluid

see table

Hydraulic fluid temperature range (NBR seals)

°C

-30 … +80

Hydraulic fluid temperature range (FKM seals)

°C

-20 … +80

Viscosity range

mm²/s

2.8 … 500

Maximum admissible degree of contamination of the hydraulic fluid 1)

Class 20/18/15 according to ISO 4406 (c)
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

electrical

Voltage type

Direct voltage AC voltage 50/60 Hz

Available voltages 1)

V

12 / 24 / 96 / 205 110 / 230

Voltage tolerance

Nominal voltage

%

± 10 ± 10

Power consumption

W

30 -

Holding power

VA

- 50

Switch-on power

VA

- 220

Duty cycle

%

100 100

Switching time according to ISO 6403 2)

On

ms

20 … 45 10 … 20

Off

ms

10 … 25 15 … 40

Maximum switching frequency

1/h

15000 7200

Maximum coil temperature 3)

°C

150 180

Protection class according to DIN EN 60529

IP65 (with mating connector mounted and locked)
1) Special voltages available upon request
2) The switching times were determined at a hydraulic fluid temperature of 40 °C and a viscosity of 46 mm2/s. Deviating hydraulic fluid temperatures can result in different switching times. Switching times change dependent on operating time and application conditions.
3) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and EN 982 need to be adhered to!The specified surface temperature in AC solenoids is valid for fault-free operation. In the error case (e. g. blocking of the control spool), the surface temperature may increase above 180 °C [356 °F]. Thus, the system must be checked for possible dangers considering the flash point (see table Hydraulic fluids).As fuse protection, circuit breakers (see table Circuit breakers) must be used, unless the creation of an ignitable atmosphere can be excluded in a different way. Thus, the surface temperature can – in the error case – be limited to maximally 220 °C [428 °F].Within a time interval of 0.6 s, the tripping current must be 8 to 10 times the nominal power supply (tripping characteristics “K”).The required non-tripping current of the fuse must not fall below the value I1 (see table Circuit breakers with tripping characteristics “K”). The maximum tripping current of the fuse must not exceed the value I2 (see table Circuit breakers with tripping characteristics “K”).The temperature dependence of the tripping behavior of the circuit breakers has to be observed according to the manufacturer's specifications.

Notices!

Actuation of the manual override is only possible up to a tank pressure of approx. 50 bar. Avoid damage to the bore of the manual override! (Special tool for the operation, separate order, material no. R900024943). When the manual override is blocked, the actuation of the solenoid must be prevented! The simultaneous actuation of the solenoids must be prevented!

Notice!

AC solenoids can be used for 2 or 3 mains; e.g. solenoid type W110 for: 110 V, 50 Hz; 110 V, 60 Hz; 120 V, 60 Hz

Circuit breakers with tripping characteristics K according to EN 60898-1 (VDE 0641-11), EN 60947-2 (VDE 0660-101), IEC 60898 and IEC 60947-2

Valve nominal voltage

Nominal power supply

Recommended fuse rated current

50 Hz

60 Hz

24

2

1,5

3

42

 

1,26

0,98

2

48

1

0,95

1,6

100

0,56

0,5

1

110

0,52

0,45

0,75

115

 

0,45

0,37

0,75

127

0,42

0,32

0,75

200

0,29

0,26

0,5

220

0,27

 

0,23

0,5

230

0,23

0,17

0,5

240

0,23

0,19

0,5

When establishing the electrical connection, the protective earthing conductor (PE ⊥) must be connected correctly.

Inductive position switch type QM: electrical connection

The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.

electrical

Connection voltage (DC voltage)

V

24

Voltage tolerance (connection voltage)

+30 %/-15 %

Admissible residual ripple

%

≤ 10

Max. load capacity

mA

400

Switching outputs

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/
PNP transistor outputs, load between switching outputs and GND

Pinout

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

1

V

24

2, 4

Switching output

mA

400

3

Earthing (GND)

V

0

For applications outside these parameters, please consult us!

Ordering code

Mains

W110

110 V, 50 Hz

110 V, 60 Hz

120 V, 60 Hz

W 230

230 V, 50 Hz

230 V, 60 Hz

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP, HLPD, HVLP, HVLPD

NBR, FKM

DIN 51524

Environmentally compatible

Insoluble in water

HETG

NBR, FKM

ISO 15380

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Containing water

HFC

NBR

ISO 12922

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qV characteristic curves

Spool symbols D27, E46, E54, E56, E57, E62, E115, E127, E129, E130, E131, E132, ,E135, E136, E138, E139, E140, E141, E144, E145, E145A, E146, E147, E166, E181 and E183 on request.

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Symbol

A➁‒A➀

A➀‒A➁

B➁‒B➀

B➀‒B➁

A➁‒B➁

B➁‒A➁

T➁‒T➀

P➁‒P➀

D24

4

1

2

4

3

2

7

7

E51

3

1

1

3

7

7

E53

2

2

2

2

5

2

7

7

E63

2

5

5

3

7

7

E68

4

4

6

5

4

5

7

7

E137

1

4

3

2

5

6

7

7

Δp-qV characteristic curves

Spool symbols X161, X163, X181, X183, X187, X188, X193 and X157 on request.

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Symbol

Spool position

A➀‒A➁

A➁‒A➀

B➀‒B➁

B➁‒B➀

T➁‒T➀

P➁‒P➀

P➀‒T➁

B➁‒T➁

P➁‒P➀

A➁‒T➁

P➁‒A➁

B➁‒T➁

X250

16

17

17

18

13

10

X252

16

17

17

18

9

11

X253

13

14

14

19

18

8

X254

16

12

13

18

18

12

X255

0

15

8

8

a

12

13

b

12

12

13

X256

12

9

9

18

18

20

Performance limits(measured with HLP46, ϑOil = 40 ±5 °C and 24 V DC voltage)

Spool symbols D27, E46, E54, E56, E57, E62, E115, E127, E129, E130, E131, E132, E133, E134, E135, E136, E138, E139, E140, E141, E144, E145, E145A, E146, E147, E166, E181, E183, X161, X163, X181, X183, X187, X188, X193 and X157 on request.

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Performance limits(measured with HLP46, ϑOil = 40 ±5 °C and 24 V DC voltage)

Spool symbols D27, E46, E54, E56, E57, E62, E115, E127, E129, E130, E131, E132, E133, E134, E135, E136, E138, E139, E140, E141, E144, E145, E145A, E146, E147, E166, E181, E183, X161, X163, X181, X183, X187, X188, X193 and X157 on request.

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Performance limits(measured with HLP46, ϑOil = 40 ±5 °C [104 ±9 °F] and 230 V AC voltage)

Spool symbols D27, E46, E54, E56, E57, E62, E115, E127, E129, E130, E131, E132, ,E135, E136, E138, E139, E140, E141, E144, E145, E145A, E146, E147, E166, E181 and E183 on request.

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Symbol

W230–50Hz​

W230–60Hz​

E63

13

16

E68

14

18

E53

15

18

E137

17

17

E51

17

17

D24

17

17

DC or AC voltage

D24

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E57

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

D27

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E62

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E46

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E63

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E51

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E68

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E53

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E115

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E54

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E127

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E56

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E129

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E130

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E138

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E131

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E139

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E132

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E140

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E1351)

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/
1) Throttle installation available on request

E141

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E136

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E144

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E137

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E145

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E145A

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E166

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E146

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E181

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E147

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

E183

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

component side

plate side

Direct voltage

X161

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X250

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X163

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X252

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X181

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X253

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X183

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X254

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X187

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X255

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X188

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X256

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X193

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

X257

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

component side

plate side

Inductive position switch type QM Switching logics

Version QMA

(Position switch on side B, monitored spool position "a")

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Version QMA

(Position switch on side A, monitored spool position "a")

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Version QMB

(Position switch on side B, monitored spool position "b")

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Version QMB

(Position switch on side A, monitored spool position "b")

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Version QM0

(Position switch on side B, monitored rest position)

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Version QM0

(Position switch on side A, monitored rest position)

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

with DC solenoid

Spool symbols D24, E51, E53, E63, E68, E137, …

Dimensions in mm

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Spool symbols X250, X252, X253, X254, X255, X256, …

Dimensions in mm

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Symbol

Solenoid side

L1

L2

L3

L4

L5

L6

L7

mm

mm

mm

mm

mm

mm

mm

X250 a 24.9 54.9 - 63.3 93.3 - -
X252 b 24.9 54.9 33.5 - - 123.1 -
X253 b 18.3 54.3 26.9 - - 129.7 -
X254 a 18.3 54.3 - 69.9 86.7 - -
X255 a + b 25.9 53.9 - - 94.3 131.1 225.4
X256 b 12 54.8 20.6 - - 136 -

Spool symbols X161, X163, X181, X183, X187, X188, X193 and X157 on request.

with AC solenoid

Dimensions in mm

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

component side – porting pattern according to ISO 4401-03-02-0-05 (with or without locating hole); (with locating hole Ø3 x 5 mm deep)

plate side – porting pattern according to ISO 4401-03-02-0-05 (with locating hole for locking pin ISO 8752-3x8-St; version "/60" and "/62")

3

Dimension for valve without manual override

4

Dimension for solenoid with concealed manual override "N9" (standard)

5

Dimension for valve with manual override "N"

6

Mating connector without circuitry (separate order, see data sheet 08006)

7

Mating connector with circuitry (separate order, see page data separate order, see data sheet 08006)

8

Space required to remove the mating connector

9

Identical seal rings for ports A, B, P, T (plate side)

10

Name plate

11

Plug screw for valve with one solenoid

12

Locking pin ISO 8752-3x8-St (only version "/62")

Subplates according to data sheet 45052

(separate order)

(without locating hole)

G 341/01 (G1/4)

G 342/01 (G3/8)

G 502/01 (G1/2)

(with locating hole)

G 341/60 (G1/4)

G 342/60 (G3/8)

G 502/60 (G1/2)

Valve mounting screws (separate order)

– 4 hexagon socket head cap screws ISO 4762 - M5 - 10.9-flZn-240h-L

with friction coefficient µtotal = 0.09 to 0.14,

tightening torque MA = 7 Nm ±10 %

or

– 4 hexagon socket head cap screws ISO 4762 - M5 - 10.9

with friction coefficient µtotal = 0.12 to 0.17,

tightening torque MA = 8.1 Nm ±10 %

Notice!

Length and tightening torque of the valve mounting screws must be calculated according to the components mounted under and over the sandwich plate valve.

Spool position monitoring

Inductive position switch type QM

Dimensions in mm

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/
1) For dimensions, see valve dimensions

Dimensions in mm

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Notice:

The dimensions are nominal dimensions which are subject to tolerances.

Mating connectors for valves with connector “K4”, without circuitry, standard

3P Z4

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Mating connectors for valves with connector “K4”, without circuitry, standard

3P Z4

For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)

Data sheet

Spare parts & repair

Mating connectors for valves with connector “K4”, with indicator light

3P Z5L

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Mating connectors for valves with connector “K4”, with indicator light

3P Z5L

For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)

Data sheet

Spare parts & repair

Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit

3P Z5L1

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit

3P Z5L1

For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)

Data sheet

Spare parts & repair

Mating connectors for valves with connector “K4”, with rectifier

3P RZ5

technical illustration-Z4WE6E137-3X/EG24N9K4-Directional spool valves: Z4W*  6.-3x/

Mating connectors for valves with connector “K4”, with rectifier

3P RZ5

For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)

Data sheet

Spare parts & repair