Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
LFA16DRW2-7X/150
R901086754
Directional Seat/Poppet Valves

Logic covers: LFA 16.-7x/

$1,483.00

BOSCH REXROTH

MATERIAL:  R901086754

SUMMARY:  Logic covers: LFA 16.-7x/

Quantity in stock: 2

Quantity Details:
  • Hydrotech Stock: 0 can ship April 19, 2024
  • Factory Stock: 2 can ship July 19, 2024
Add to Cart

General

2-way cartridge valves for pressure functions are pilot-operated valves in seat or spool design. The power section designed as cartridge valve (1) is installed into a receiving hole standardized according to DIN ISO 7368 and closed with a control cover (2).

The pilot control valve (4) for manual or electrically proportional pressure adjustment is integrated into the control cover (2) or is installed on the control cover (2) as pilot valve with mounting dimensions according to DIN 24 340.

By combination of cartridge valves with the control covers, different pressure functions can be realized. .

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

Pressure reducing function

Rest position closed

For the pressure reducing function with opening characteristic, a pressure limitation cartridge valve (type LC..DB40D...) and a control cover with a pressure reducing pilot control valve (type LFA..DR...) are applied. The pilot oil is directed from port A via the supply orifice and the opened pilot control valve to side B.

The main spool is opened and the flow from port A to port B is released.

On reaching the set pressure, the spool is closed and the pressure at port B is reduced according to the pressure-flow characteristics. Potential pressure increases on the secondary side are discharged to the tank via the 3rd way of the pilot control valve. Set-up of a directional valve enables realization of an additional blocking function (type LFA..DRW...).

Control cover for pressure reducing function

01

02

03

04

05

06

07

LFA

DRW

7X

/

Type

01

Control cover LFA

LFA

Size

02

NG 16

16

NG 25

25

NG 32

63

NG 40

40

NG 50

50

NG 63

63

NG 80

80

NG 100

100

Version

03

Pressure reducing function - Main spool in rest position closed (LC..DB 40 D..- separate order)

DRW

Adjustment type for pressure adjustment

04

Rotary knob

1

Sleeve with hexagon and protective cap

2

Lockable rotary knob with scale, incl. H-key

3

Rotary knob with scale

4

Component series

05

Component series 70 ... 79 (70 ... 79: unchanged installation and connection dimensions)

7X

Pressure rating DBmax. (observe admissible pressure of the pilot control valve)

06

Set pressure up to 25 bar

025

Set pressure up to 75 bar

075

Set pressure up to 150 bar

150

Set pressure up to 210 bar

210

Set pressure up to 315 bar

315

Seal material

07

NBR seals

no code

FKM seals

V

Additional preferred types and standard units are specified in the EPS (standard price list).

Main spool in rest position closed - LC..DB 40 D..- separate order

Orifice symbol

Symbol in ordering code

A**

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

A**

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

This orifice is designed as screw-type orifice. If an orifice is to be installed, the respective code letter with the orifice Ø in 1/10 mm has to be entered in the type designation. Example: A12 = Orifice with Ø1.2 mm in channel A.

Ø1,2

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/ technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

This orifice is designed as bore. No specifications are made in the type designation. (Orifice Ø in mm)

Z12

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/ technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

This orifice is designed as screw-type orifice. This is a standard orifice. No specifications are made in the type designation. (Orifice Ø in 1/10 mm)

general

Size

16 25 32 40 50 63

hydraulic

Size

16 25 32 40 50 63

Hydraulic fluid

see table

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

mm²/s

2.8 … 380

Maximum admissible degree of contamination of the hydraulic fluid 1)

Class 20/18/15 according to ISO 4406 (c)
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

FKM, NBR

DIN 51524

Bio-degradable

Insoluble in water

HEES (synthetic esters)

FKM

VDMA 24568

HETG (rape seed oil)

FKM, NBR

Soluble in water

HEPG (polyglycols)

FKM

VDMA 24568

Other hydraulic fluids on request

Control cover

Size

16 25 32 40 50 63

maximum admissible operating pressure in port ...

...X (primary pressure)

bar

315

...Y (secondary pressure = max. set pressure)

bar

315

...Z2

static

bar

60

at pressure control

depressurized (up to ≈ 2 bar)

For applications outside these parameters, please consult us!

Attention!

Control covers type LFA..DR... are combined with 2-way cartridge valves type LC..DB 40 D... (see ordering code).

The control covers are equipped with standard orifice fitting – optimized in our test area. Orifice specification in the type key is not necessary. Deviating operating conditions may require respective adjustment of the orifice size. The orifices are designed as screw-type orifices.

Orifice representation in symbol

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

(basic symbol) - Pressure reducing function

LFA..DRW.-7X/...NG 16

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

LFA..DRW.-7X/...NG 25, 32

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

LFA..DRW.-7X/...NG 40, 50

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

LFA..DRW.-7X/...NG 63

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

Installation bore and connection dimensions according to ISO 7368

NG16 ... 63

Dimensions in mm

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

NG 16, 25, 32

Dimensions in mm

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

1

Port X optionally as threaded port (at NG 16...50)

3.1

Port Z1 optionally as threaded port (at LFA..DREZ.. , LFA..DREWZ..., NG 25..63)

4

Locating pin

9.1

Name plate (NG16)

9.2

Name plate (NG 25, 32)

NG 40, 50

Dimensions in mm

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

1

Port X optionally as threaded port (at NG 16...50)

2

Port Y optionally as threaded port (at NG 40, 50)

3.1

Port Z1 optionally as threaded port (at LFA..DREZ.. , LFA..DREWZ..., NG 25..63)

3.2

Port Z2 optionally as threaded port (at NG 40, 50, 63)

4

Locating pin

9.3

Name plate (NG 40, 50, 63)

10

Check valve (at NG 63 orifice F in poppet)

NG63

Dimensions in mm

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

3.1

Port Z1 optionally as threaded port (at LFA..DREZ.. , LFA..DREWZ..., NG 25..63)

3.2

Port Z2 optionally as threaded port (at NG 40, 50, 63)

4

Locating pin

9.3

Name plate (NG 40, 50, 63)

10

Check valve (at NG 63 orifice F in poppet)

11

At control cover NG 63, logic element NG 16

NG16 ... 63

Dimensions in mm

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

Notice:

The dimensions are nominal dimensions which are subject to tolerances.

Mounting screws (included in scope of delivery)

Hexagon socket head cap screw according to DIN 912-10.9

NG

Quantity

Dimensions

Tightening torque in Nm

16

4

M 8 x 45

32

25

4

M 12 x 50

110

32

4

M 16 x 60

270

40

4

M 20 x 70

520

50

4

M 20 x 80

520

63

4

M 30 x 100

1800

5.1

Adjustment element "4"

5.2

Adjustment element "3"

6

Adjustment element "2"

7

Adjustment element "1"

8

direct operated pressure reducing valve (included in the scope of delivery)

9

Name plate of the pressure reducing valve

11

Valve mounting screws M5x50 DIN 912-10.9 MA = 8.9 Nm are included in the scope of delivery of the control cover

12

Pressure gauge connection G1/4; 12 mm deep; internal hexagon SW6

13

Space required to remove the key

14

Control cover

15

Lock nut SW24

16

at type .../315 → 50 mm

NG

H1

H2

H3

L1

L2

L3

L7

mm

mm

mm

mm

mm

mm

mm

16 40
-
17
-
15 65
-
80 36.5 49
25 40
-
19
-
24 85
-
85 49 59
32 50
-
26
-
28 100
-
100 56.5 66.5

Valve dimensions

NG

Ø Orifice A**

Ø Orifice X** 1)

Ø Orifice F**

Ø Orifice D**

L8

L9

L10

L11

L12

.../315

.../315

.../315

.../315

.../315

.../315

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

16 - 2.5 - 0.8 1) 0.8 1) 18 30.5 123.5 116.5 147.5 140.5 103.5 96.5 103.5 96.5
25 - - 0.8 1) 3 2) 1.8 2) 2 14 135 128 159 152 115 108 115 108
32 - - 1 1) 3 2) 1.8 2) - 6 127.5 120.5 152.5 145.5 107.5 100.5 107.5 100.5
40 - - 1.2 1) 3 2) 1.8 2) - - 115 108 139 132 95 88 95 88
50 - - 1.5 1) 3 2) 1.8 2) - - 107.5 100.5 129.5 125.5 87.5 80.5 87.5 80.5
63 2 1) - 1.5 1) 3 1) 1.8 1) - - 91.5 84.5 112.5 108.5 71.5 64.5 71.5 64.5
1) Orifice Ø, orifice M6 conical
2) Orifice Ø, orifice M8 x 1 conical

NG

H1

H2

H3

H4

H5

L1

L2

L3

L4

L5

L7

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

40 60
-
30
-
32 40 40 125
-
125 72 62.5 62.5 79
50 68
-
32
-
34 32 32 140
-
140 80 70 70 86.5

Directional spool valves, direct operated, with solenoid actuation

WE 6...E

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

Directional spool valves, direct operated, with solenoid actuation

WE 6...E

Size 6 Component series 6X Maximum operating pressure 350 bar Maximum flow (DC) 80 l/min Maximum flow (AC) 60 l/min

Data sheet

Configurator / CAD

Spare parts & repair

4/3, 4/2 and 3/2 directional valve with wet-pin DC solenoids

WE 6...E...407

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

4/3, 4/2 and 3/2 directional valve with wet-pin DC solenoids

WE 6...E...407

Size 6 Component series 6X Maximum operating pressure 315 bar Maximum flow 60 l/min

Data sheet

Configurator / CAD

General product information on hydraulic products

Installation, commissioning and maintenance of industrial valves

Spare parts & repair

Directional spool valves, direct operated, with solenoid actuation

WE 6...E...UR

technical illustration-LFA16DRW2-7X/150-Logic covers: LFA 16.-7x/

Directional spool valves, direct operated, with solenoid actuation

WE 6...E...UR

Solenoid coil is an approved component with UR-marking according to UL 906 Size 6 Component series 6X Maximum operating pressure 350 bar Maximum flow (DC) 80 l/min Maximum flow (AC) 60 l/min

Data sheet

Spare parts & repair