Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
R901211014
Pressure Reducing Valves

Pressure valves: 3DR,3DR3U 10.-6x/

$4,547.00

BOSCH REXROTH

MATERIAL:  R901211014

SUMMARY:  Pressure valves: 3DR,3DR3U 10.-6x/

Add to Cart

The pressure valve type 3DR is a pilot-operated 3-way pressure reducing valve with pressure limitation of the secondary circuit. It is used to reduce the system pressure.

The pressure reducing valve basically consists of the main valve (1) with control spool (2) and pilot control valve (3) with pressure adjustment element (10).

The valve is open in initial position. Hydraulic fluid can flow from channel P to channel A without restrictions. The pressure in channel A is simultaneously applied via the bore (4) at the piston area opposite the compression spring (9). Simultaneously, pressure is applied via the nozzle (6) to the spring-loaded side of the control spool (2) and via channel (5) to

ball (7) in the pilot control valve (3). Depending on the setting of the compression spring (11), pressure builds up upstream of the ball (7) and in channel (5) holding the control spool (2) in open position. Hydraulic fluid flows from channel P via the control spool (2) to channel A until a pressure builds up in channel A exceeding the pressure value set at the compression spring (11) and opening the ball (7).

The control spool (2) moves to closed position. The desired reduced pressure is reached if there is a balance between the pressure in channel A and the pressure value set at the compression spring (11).

If the pressure in channel A increases further due to an external force effect at the actuator, the control spool (2) is pushed further against the compression spring (9). In this way, channel A is connected to channel T via the control edge (8) at the control spool (2). So much hydraulic fluid is discharged into the tank that the pressure can no longer increase. The pilot oil return from the spring chamber (12) is always realized externally via the control line (13) at port Y. A depressurized connection to the tank must always be ensured.

The pressure gauge connection (14) enables control of the reduced pressure in channel A.

Type 3DR 10 P4–6X/…

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

01

02

03

04

05

06

07

08

09

10

3DR

10

P

6X

/

Y

/

00

*

01

3-way pressure reducing valve

3DR

02

Size 10

10

03

Subplate mounting

P

Adjustment element

04

Rotary knob

4

Sleeve with hexagon and protective cap

5

Lockable rotary knob with scale

6 1)

Rotary knob with scale

7

05

Series 60 to 69 (60 to 69: unchanged installation and connection dimensions)

6X

06

Set pressure up to 50 bar

50

Set pressure up to 100 bar

100

Set pressure up to 200 bar

200

Set pressure up to 315 bar

315

Pilot oil flow

07

Internal pilot oil supply, external pilot oil return

Y

08

With stroke limitation

00

09

NBR seals

M

FKM seals (other seals upon request)

V

Observe compatibility of seals with hydraulic fluid used.

10

Further details in the plain text

*

1) H-key with material no. 00008158 is included in the scope of delivery.

Preferred types and standard units are specified in the EPS (standard price list).

general

Size

10

Weight

kg

6

Installation position

any

Direction of flow

see symbol

Ambient temperature range

°C

-30 … +50

hydraulic

Size

10

Nominal pressure

bar

315

Maximum operating pressure

Port P

bar

315

Anschluss A

bar

315

Port Y

separate and depressurized to the tank

Set pressure

Minimum

flow-dependent, see characteristic curves

Maximum

bar

50
100
200
315

Maximum flow

l/min

120

Hydraulic fluid

see table

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

mm²/s

10 … 800

Maximum admissible degree of contamination of the hydraulic fluid

Class 9 according to NAS 1638. For this, we recommend using a filter with a minimum retention rate of β10 ≥ 75.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oil

HL, HLP

FKM, NBR

DIN 51524

Bio-degradable

Insoluble in water

HEES (synthetic esters)

FKM

VDMA 24568

HETG (rape seed oil)

FKM, NBR

Soluble in water

HEPG (polyglycols)

FKM

VDMA 24568

Other hydraulic fluids on request

1) Suitable for NBR and FKM seals
2) Suitable for FKM seals only

For applications outside these parameters, please consult us!

(measured at v = 41 mm2/s and ϑ = 50 °C)

Outlet pressure pA dependent on the flow qV

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

The characteristic curves apply for outlet pressurepT = zero in the entire flow range.

Flow resistance

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

Minimum set pressure pmin dependent on the flow qV

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

The characteristic curves apply for outlet pressure pT = zero in the entire flow range.

Pilot flow qV st dependent on the flow qV

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/
technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

Dimensions in mm

technical illustration-R901211014-Pressure valves: 3DR,3DR3U 10.-6x/

1

Name plate

2

Pilot control valve

3

Main valve

4

Adjustment element "5"

5

Hexagon SW10

6

Adjustment element "4"

7

Adjustment element "6"

8

Adjustment element "7"

9

O-rings 10.82 x 1.78 for ports X and Y

10

O-rings 12 x 2 for ports A, B, P and T

11

Port X must be closed in the subplate

12

Port B must be closed in the subplate

13

Pressure gauge connection

14

Valve contact surface, porting pattern according to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H

Subplates

G535/01 (G 3/4)

G536/01 (G 1)

must be ordered separately.

Valve mounting screws

4 x M6 x 45 DIN 912-10.9,

MA = 15,5 Nm,

must be ordered separately.