M-3SED6CK1X/350CW110RN9XEZ2/V
R901270798
Directional Seat/Poppet Valves

Direct. poppet valves: M-*SED 6.-1x/

$2,524.00

BOSCH REXROTH

MATERIAL:  R901270798

SUMMARY:  Direct. poppet valves: M-*SED 6.-1x/

Add to Cart

3/2 directional seat valve

General information

Directional valves of type SED are direct operated directional seat valve with solenoid actuation.

They control start, stop and direction of flow.

The directional valves basically consists of a housing (1), the solenoid (2), the valve seats (7) and (11) as well as of the control spool (4).

The manual override (6) allows for the switching of the valve without solenoid energization.

Basic principle

The initial position of the valve (normally open "UK" or normally closed "CK") is determined by the arrangement of the spring (5). The chamber (3) behind the control spool (4) is connected to port P and sealed against port T. Thus, the valve is pressure-compensated in relation to the actuating forces (solenoid and spring).

By means of the control spool (4), the ports P, A and T can be loaded with the maximum operating pressure (350 bar) and the flow can be directed in both directions (see symbols).

In the initial position, the control spool (4) is pressed onto the seat (11) by the spring (5), in spool position, it is pressed onto the seat (7) by the solenoid (2). The flow is blocked.

Seat valves can be used according to the spool symbols as well as the assigned operating pressures and flows (see chapter "Technical data" - table "Performance limits (measured with HLP46, ϑoil = 40 ±5 °C)").

The seat arrangement offers the following options:

Symbol

UK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

CK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Type M-3SED 6 UK...

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Throttle insert "...B"

The use of a throttle insert is required when, due to prevailing operating conditions, flows occur during the switching processes, which exceed the performance limit of the valve.

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
1) Seal ring

4/2 directional seat valve

With a sandwich plate, the Plus-1 plate, under the 3/2 directional seat valve, the function of a 4/2 directional seat valve is achieved.

Function of the Plus-1 plate

Initial position:
The main valve is not actuated. The spring (5) holds the control spool (4) on the seat (11). Port P is blocked and A is connected to T. Apart from that, one control line is connected from A to the large area of the control spool (8), which is thus unloaded to the tank. The pressure applied via P now pushes the ball (9) onto the seat (10). Now, P is connected to B, and A to T. Transition position:
When the main valve is actuated, the control spool (4) is shifted against the spring (5) and pressed onto the seat (7). During this, port T is blocked, P, A, and B are briefly connected to each other. Spool position:
P is connected to A. As the pump pressure acts via A on the large area of the control spool (8), the ball (9) is pressed onto the seat (12). Thus, B is connected to T, and P to A. The ball (9) in the Plus-1 plate has a "positive spool overlap".

 

Notice:

If the annulus area of differential cylinders is not connected to port A, a pressure peak is created in port B during the switching process. This pressure peak may exceed the maximum admissible operating pressure over the permissible limit.

The use of the Plus-1 plate and the seat arrangement offer the following options:

Symbol

D

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Y

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Schematic illustration: Initial position

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Type M-4SED 6 Y...

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
1) 3/2 directional seat valve
2) Plus-1 plate

Throttle insert, check valve insert

Throttle insert

Check valve insert

The use of a throttle insert is required if, due to the operating conditions given, flows may arise during the switching processes which exceed the performance limit of the valve.

Examples:

Accumulator operation, use as pilot control valve with internal pilot fluid tapping.

3/2 directional seat valve

The throttle insert is inserted into port P of the seat valve.

4/2 directional seat valve

The throttle insert is inserted into port P of the Plus-1 plate.

 

The check valve insert allows a free flow from P to A and closes A to P.

3/2 directional seat valve

The check valve insert is inserted into port P of the seat valve.

4/2 directional seat valve

The check valve insert is inserted into port P of the Plus-1 plate.

 

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/ technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

01

02

03

04

05

06

07

08

09

10

11

12

13

14

M

SED

6

1X

/

350

C

XE

Z2

/

01

Mineral oil

M

02

3 main ports

3

4 main ports

4

03

Seat valve

SED

04

Size 6

6

Symbols

05

Main ports

3

4

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

UK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

CK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

D

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Y

06

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

07

Operating pressure up to 350 bar

350

08

Solenoid, wet (wet-pin), with detachable coil

C

09

Direct voltage 24 V

G24

Alternating voltage 230 V, 50/60 Hz

W230R

For further ordering codes for other voltages and frequencies, see chapter "Technical data"

10

With concealed manual override

N9

Without manual override

no code

Explosion protection

11

"Increased safety", for details see chapter "Technical data" - Table "Information on the explosion protection"

XE

Electrical connection

12

Solenoid with terminal box and cable gland, for details see chapter "Electrical connection"

Z2

13

Without check valve insert, without throttle insert

no code

With check valve insert

P

Throttle Ø 1.2 mm

B12

Throttle Ø 1.5 mm

B15

Throttle Ø 1.8 mm

B18

Throttle Ø 2.0 mm

B20

Seal material

14

NBR seals

no code

FKM seals

V

Observe compatibility of seals with hydraulic fluid used. (Other seals upon request)

Notice:
Representation of the symbols according to DIN ISO 1219-1.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP, HLPD

NBR, FKM

DIN 51524

90220

Bio-degradable

Insoluble in water

HETG

NBR, FKM

ISO 15380

90221

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Important information on hydraulic fluids:

For further information and data on the use of other hydraulic fluids, please refer to the data sheets above or contact us. There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). Ignition temperature >180 °C

electrical

Voltage type

Direct voltage AC voltage

Available voltages

V

24 / 48 / 96 / 110 110 / 230

Voltage tolerance (nominal voltage)

%

- 5
+ 10

Admissible residual ripple

%

< 5 -

Duty cycle/operating mode according to VDE 0580

S1 (continuous operation)

Switching time according to ISO 6403

see table

Maximum switching frequency

1/h

15000 7200

Nominal power with ambient temperature 20 °C

W

17

Maximum power with 1.1 x nominal voltage and an ambient temperature of 20 °C

W

20.6

Protection class according to DIN EN 60529 1)

IP66
1) With correctly installed electrical connection

Special application conditions for a safe application

Maximum ambient temperature:
In case of bank assembly, as long as only one solenoid is energized at a time, and in case of individual assembly: +70 °C
In case of bank assembly, if more than one solenoids are energized simultaneously: +60 °C The maximum temperature of the surface of the valve jacket is 120 °C. This has to be considered when selecting the connection cable and/or contact of the connection cable with the surface of the jacket is to be prevented.

Switching times t in ms (installation position: solenoid horizontal)

Pressure p

Flow qV

DC solenoid

AC solenoid

tON

without tank pressure

tOFF

tON

without tank pressure

tOFF

UK

CK

D

Y

CK, UK

D, Y

UK

CK

D

Y

UK

CK

D

Y

70 bar

25 l/min

50

45

55

50

10

10

50

65

55

70

50

45

55

50

140 bar

25 l/min

65

45

70

50

10

15

55

65

60

70

50

50

55

55

210 bar

25 l/min

75

55

80

60

10

15

65

65

70

70

50

55

55

60

280 bar

25 l/min

90

55

95

60

15

20

80

65

85

70

50

65

55

70

315 bar

25 l/min

95

55

100

60

15

20

95

65

100

70

50

65

55

70

350 bar

25 l/min

100

55

105

60

20

25

110

65

115

70

50

65

55

70

Notice:

The switching times were determined at a hydraulic fluid temperature of 40 °C and 46 mm2/s. Deviating hydraulic fluid temperatures can result in different switching times. Switching times change dependent on operating time and application conditions.

Performance limits (measured with HLP46, ϑoil = 40 ±5 °C)

Symbol

Comment

Operating pressure in bar

Flow in l/min

P

A

B

T

2-way circuit

UK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

With 2/2-way circuits, port P or T must be closed by the customer!

350

350

350

25

CK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

350

350

350

25

3-way circuit

UK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

350

350

350

25

CK

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

350

350

350

25

4-way circuit (flow only possible in the direction of arrow!)

D

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

3/2 directional valve (symbol “UK”) in connection with Plus-1 plate: pP ≥ pA ≥ pB ≥ pT

350

350

350

pP/pA/pB-40

25

Y

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

3/2 directional valve (symbol “CK”) in connection with Plus-1 plate: pP ≥ pA ≥ pB ≥ pT

350

350

350

pP/pA/pB-40

25

Notice

The switching power limits were established while the solenoids were at operating temperature, at 10 % undervoltage and without tank preloading.

Please observe the general notes (see chapter "Information").

(measured with HLP46, ϑoil =40 ±5 °C)

Δp-qV characteristic curves ‒ 3/2 directional seat valve

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Δp-qV characteristic curves ‒ 4/2 directional seat valve

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Δp-qV characteristic curves ‒ Check valve insert

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Δp-qV characteristic curves ‒ throttle insert

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

The type-examination tested valve solenoid of the valve is equipped with a terminal box and a type-tested cable gland.

The connection is polarity-independent.

Solenoids to be connected to AC voltage are equipped with an integrated rectifier.

Notice

When establishing the electrical connection, the protective grounding conductor (PE) has to be connected properly.

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Properties of the connection terminals and mounting elements

Position

Function

Connectable line cross-section

1

Operating voltage connection

Single-wire 0.75 … 2.5 mm2

Finely stranded,0.75 … 1.5 mm2

2

Connection for protective earthing conductor

Single-wire 2.5 mm2 max.

Finely stranded, 1.5 mm2 max.

3

Connection for potential equalization conductor

Single-wired, 4 … 6 mm2

Finely stranded, 4 mm2

Direct voltage, polarity-independent

AC voltage

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/ technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Over-current fuse and switch-off voltage peak

Voltage data in the valve type code

Nominal voltage valve solenoid

Rated current valve solenoid

Rated current for external miniature fuse: Medium time-lag (M) according to DIN 41571 and EN/IEC 60127

Rated voltage of external miniature fuse: Medium time-lag (M) according to DIN 41571 and EN/IEC 60127

Maximum voltage value when switching off

Interference protection circuit

G24

24 V DC

0.708 A DC

800 mA

250 V

–90 V

Suppressor diode bi-directional

G48

48 V DC

0.354 A DC

400 mA

250 V

–200 V

G96

96 V DC

0.177 A DC

200 mA

250 V

–370 V

G110

110 V DC

0.155 A DC

200 mA

250 V

–390 V

W110R

110 V AC

0.163 A AC

200 mA

250 V

–3 V

Bridge rectifier and suppressor diode

W230R

230 V AC

0.078 A AC

80 mA

250 V

–3 V

Notice:

A fuse which corresponds to the rated current according to DIN 41571 and EN / IEC 60127 has to be connected upstream of every valve solenoid (max. 3 x Irated).

The shut-off threshold of the fuse has to match the prospective short-circuit current of the supply source.

The prospective short-circuit current of the supply source may amount to a maximum of 1500 A.

This fuse may only be installed outside the potentially explosive atmosphere or must be of an explosion-proof design.

When inductivities are switched off, voltage peaks result which may cause faults in the connected control electronics.

The voltage peak must be damped by a suitable external circuitry.

We recommend a circuitry with a suppressor diode with a limitation voltage of approx. 50 V.

3/2 directional seat valve – version “UK"

Dimensions in mm

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Required surface quality of the valve contact surface

1

Solenoid coil

2

Concealed manual override “N9”

3

Mounting nut with hexagon SW32

4

Terminal box

5

Identical seal rings for ports A, B, T; seal ring for port P

6

Name plate

7

Porting pattern according to ISO 4401-03-02-0-05 (but without locating hole)

8

Port B is designed as blind counterbore

9

Space required to remove the solenoid coil

Valve mounting screws (separate order)

For reasons of stability, exclusively use the following valve mounting screws:

4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L

(friction coefficient µtotal = 0.09 … 0.14);

material no. R913000064

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

 

Notice:

Subplates are no components in the sense of directive 2014/34/EU and can be used after the manufacturer of the overall system has conducted an assessment of the risk of ignition.

The "G...J3" versions are free from aluminum and/or magnesium and galvanized.

3/2 directional seat valve – version "CK"

Dimensions in mm

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Required surface quality of the valve contact surface

1

Solenoid coil

2

Concealed manual override “N9”

3

Mounting nut with hexagon SW32

4

Terminal box

5

Identical seal rings for ports A, B, T; seal ring for port P

6

Name plate

7

Porting pattern according to ISO 4401-03-02-0-05 (but without locating hole)

8

Port B is designed as blind counterbore

9

Space required to remove the solenoid coil

Valve mounting screws (separate order)

For reasons of stability, exclusively use the following valve mounting screws:

4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L

(friction coefficient µtotal = 0.09 … 0.14);

material no. R913000064

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

 

Notice:

Subplates are no components in the sense of directive 2014/34/EU and can be used after the manufacturer of the overall system has conducted an assessment of the risk of ignition.

The "G...J3" versions are free from aluminum and/or magnesium and galvanized.

4/2 directional seat valve – version “D”

Dimensions in mm

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Required surface quality of the valve contact surface

Valve mounting screws (included within the scope of delivery)

For reasons of stability, exclusively use the following valve mounting screws:

4 hexagon socket head cap screws ISO 4762 - M5 x 95 - 10.9-flZn-240h-L

(friction coefficient µtotal = 0.09 … 0.14);

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

 

Notice:

Subplates are no components in the sense of directive 2014/34/EU and can be used after the manufacturer of the overall system has conducted an assessment of the risk of ignition.

The "G...J3" versions are free from aluminum and/or magnesium and galvanized.

4/2 directional seat valve, version “Y”

Dimensions in mm

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/
technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Required surface quality of the valve contact surface

Valve mounting screws (included within the scope of delivery)

For reasons of stability, exclusively use the following valve mounting screws:

4 hexagon socket head cap screws ISO 4762 - M5 x 95 - 10.9-flZn-240h-L

(friction coefficient µtotal = 0.09 … 0.14);

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

 

Notice:

Subplates are no components in the sense of directive 2014/34/EU and can be used after the manufacturer of the overall system has conducted an assessment of the risk of ignition.

The "G...J3" versions are free from aluminum and/or magnesium and galvanized.

Installation conditions (dimensions in mm)

Individual assembly

Bank assembly

Subplate dimensions

Minimum dimensions:
Length ≥ 64, width ≥ 58, height ≥ 25

Minimum cross-section:
Height ≥ 60, width ≥ 85

Thermal conductivity of the subplate (EN-GJS-500-7)

≥ 38 W/mK

Minimum distance between the longitudinal valve axes

≥ 55

Dimensions in mm

technical illustration-M-3SED6CK1X/350CW110RN9XEZ2/V-Direct. poppet valves: M-*SED 6.-1x/

Notice:

Observe the “Special application conditions for a safe application” in chapter "Technical data".

1

Solenoid coil

2

Concealed manual override “N9”

3

Mounting nut with hexagon SW32

4

Terminal box

5

Identical seal rings for ports A, B, T; seal ring for port P

6

Name plate

7

Porting pattern according to ISO 4401-03-02-0-05 (but without locating hole)

8

Plus-1 plate

9

Valve mounting screws

10

Space required to remove the solenoid coil

General Information

Seat valves can be used according to the control spool symbols and the related operating pressures and flows (see chapter "Technical data" - table "Performance limits (measured with HLP46, ϑoil = 40 ±5 °C)").

In order to ensure a safe functioning, it is absolutely necessary to observe the following:

Seat valves have a negative spool overlap, i.e. leakage oil occurs during the switching process. However, this process takes place within such a short time that it is irrelevant in nearly all cases of use. The indicated maximum flow must not be exceeded (if applicable, use a throttle insert for flow limitation.

Plus-1 plate:

When using the Plus-1 plate (4/2 directional function), the following lower operating values are to be observed:
pmin = 8 bar, qV > 3 l/min. The ports P, A, B and T are clearly specified according to their tasks. They must not be exchanged or closed. Port T must always be connected. The pressure level and the pressure distribution are to be observed. The flow is only admissible in the direction of arrow.