This module is designed for use within an Inline station. If the maximum load on the bus coupler for the logic voltage (UL) has been reached, then you can use this module in order to provide this voltage again. To do so, a 24 V DC voltage (U24 V) is applied at the module; this voltage generates the logic voltage (UL).
General data
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Color |
Gray | |
Weight 1) |
g |
65 |
Mounting type |
Support rail | |
Ambient temperature (operation) |
-25 °C ... +55 °C | |
Ambient temperature (storage/transport) |
-25 °C ... +85 °C | |
Permissible relative humidity (operation) |
10 % ... 95 %, EN 61131-2 | |
Permissible relative humidity (storage/transport) |
10 % ... 95 %, EN 61131-2 | |
Air pressure (operation) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Air pressure (storage/transport) |
70 kPa ... 106 kPa (up to 3000 m above sea level) | |
Protection type |
IP20 | |
Protection class |
III, IEC 61140, EN 61140, VDE 0140-1 |
1) | Including plug |
Connection data
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Designation |
Inline connection plug | |
Connection type |
Spring-cage connection | |
Conductor cross-section solid/flexible/AWG |
0.08 mm² ... 1.5 mm² 0.08 mm² ... 1.5 mm² 28 ... 16 |
Interface local bus
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Transmission speed |
kBit/s MBit/s |
500 2 |
Inline potentials/performance balance
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
24 V power feed U24V for generating UL |
V DC |
24 |
Supply voltage range U24V |
19.2 V DC ... 30 V DC (including all tolerances, including ripple) | |
Minimum current consumption from U24V |
mA |
13 |
Maximum current consumption from U24V |
mA |
274 |
Logic voltage UL 1) |
7.5 V DC ±5 % | |
Power supply to UL |
A |
≤ 0.8 |
Overvoltage protection |
Yes; input protection diodes are destroyed by permanent overload. Pulse loads up to 1500 W are short-circuited by the input protection diode. | |
Reverse polarity protection |
Serial diode in the feed path of the mains power supply; in the event of a fault, only low current flows. In the event of a fault no fuse is tripped in the external mains power supply. If you want to install a fuse for the 24-V power feed, use a fuse with 2 A time-lag. |
1) | Via potential jumpers |
Power dissipation
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Power dissipation (device) |
≤0.6 W (device total) |
PROFIBUS telegram data
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Need for parameter data |
byte |
0 |
Need for configuration data |
byte |
0 |
Electrical isolation/insulation of the voltage ranges
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Test distance |
Test voltage | |
7.5 V-logic, 24 V analog supply/function earth |
500 V AC, 50 Hz, 1 min. | |
7.5 V logic, 24 V analog supply/24 V main, 24 V segment supply |
500 V AC, 50 Hz, 1 min. | |
24 V main, 24 V segment supply/function earth |
500 V AC, 50 Hz, 1 min. |
Error messages to the higher-level control or computer system
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
Error message |
None |
Approvals |
The current approvals can be found at www.boschrexroth.com. |
Dimensions
Type |
R-IB IL 24 PWR IN/R/L-0.8A-PAC | |
A |
mm |
12.2 |
B |
mm |
120 |
C |
mm |
71.5 |
Note on dimensions |
The depth applies when using a support rail TH 35-7.5 (acc. to EN 60715). |