Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
320PZR06/025-2X/H6PZB00-V8,0-M
R928053404
High Pressure Filters

Block mounted filter

$814.32

BOSCH REXROTH

MATERIAL:  R928053404

SUMMARY:  Block mounted filter

Due to extremely high demand, please call 888-651-5712 for availability

Block mounting filters for sandwich plate mounting are intended for installation in vertical stackings. They basically consist of filter head (1), a screwable filter bowl (2), filter element (3) as well as mechanical/visual maintenance indicator (4). Via the inlet bore (bore P / sealing side), the hydraulic fluid reaches the filter element (3) where it is cleaned. The dirt particles filtered out settle in the filter bowl (2) and in the filter element (3). On the opposite side, the filtered hydraulic fluid enters the hydraulic circuit via the outlet bore. In size 06/025, the filter type 320PZ is available in two versions, left or right.

The filter housing is designed so that pressure peaks – as they may e.g. occur in case of abrupt opening of large control valves due to the accelerated fluid weight – can be securely absorbed. The filter material H…PZ is especially suitable for flow fluctuations which are common in this application.

By default, the filter is equipped with mechanical/visual maintenance indicator (4). The electronic switching element (5) which has to be ordered separately is attached to the mechanical/visual maintenance indicator (4) and held by means of a locking ring. The electronic switching elements with 1 or 2 switching points are connected via a mating connector according to IEC-60947-5-2 or via a cable connection according to EN 17301-803.

 

Notice:

Assignment of the connection designation see chapter “Dimensions”.

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filtertechnical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

01

02

03

04

05

06

07

08

09

320PZ

2X

/

B00

Series

01

Sandwich plate filter, simple, 320 bar

320PZ

Filter bowl position

02

Right

R

Left

L

Size

03

PZR…

06/025

10/075

10/125

PZL…

06/025

Component series

04

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6

2X

Filter rating in μm

05

Absolute
(ISO 16889)

Non-woven glass fiber media, not cleanable

H3PZ

H6PZ

H10PZ

H20PZ

Pressure differential

06

max. admissible pressure differential of the filter element 330 bar, without bypass valve

B00

Maintenance indicator

07

Maintenance indicator, mech./visual, switching pressure 5.0 bar

V5,0

Maintenance indicator, mech./visual, switching pressure 8.0 bar

V8,0

Seal

08

NBR

M

FKM

V

Supplementary information

09

Manufacturer's inspection certificate M according to DIN 55350 T18

Z1

Further versions are available upon request.

Hydraulic fluid

Classification

Suitable sealing materials

Suitable adhesive

Standards

Mineral oil

HLP

NBR

Standard

DIN 51424

Bio-degradable

Insoluble in water

HETG

NBR

VDMA 24568

HEES

FKM

Soluble in water

HEPG

FKM

VDMA 24568

Flame-resistant

Water-free

HFDU, HFDR

FKM

VDMA 24317

Containing water

HFAS

NBR

DIN 24320

HFAE

NBR

HFC

NBR

VDMA 24317

Skydrol

EPDM

Special “H”

general

Size

06/025 06/025 10/075 10/125

Installation position

Sandwich plate mounting

Ambient temperature range 1)

°C

-10 … +65

Weight

Filter

kg

3.5 6.5 7.2

Volume

l

0.14 0.35 0.48

Material

Filter head

GGG

Filter bowl

Steel

Seals

NBR / FKM
1) short periods down to -30 °C

hydraulic

Size

06/025 06/025 10/075 10/125

Max. operating pressure

pmax

bar

320

Flow, max.

20 l/min 36 l/min 42 l/min

Operating temperature range

-10 … +100 °C

Hydraulic fluid temperature range

-10 … +100 °C

Minimum conductivity of the medium

300 pS/m

Fatigue strength according to ISO 10771

> 10⁶ with operating pressure

Type of pressure measurement

Pressure differential

Important information on hydraulic fluids!

For more information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! Flame-resistant – containing water: Due to possible chemical reactions with materials or surface coatings of machine and system components, the service life with these hydraulic fluids may be less than expected. Filter materials made of filter paper P must not be used, filter elements with glass fiber material have to be used instead. Bio-degradable: If filter materials made of filter paper are used, the filter life may be shorter than expected due to material incompatibility and swelling.

Hydraulic fluid

Classification

Suitable sealing materials

Suitable adhesive

Standards

Mineral oil

HLP

NBR

Standard

DIN 51424

Bio-degradable

Insoluble in water

HETG

NBR

VDMA 24568

HEES

FKM

Soluble in water

HEPG

FKM

VDMA 24568

Flame-resistant

Water-free

HFDU, HFDR

FKM

VDMA 24317

Containing water

HFAS

NBR

DIN 24320

HFAE

NBR

HFC

NBR

VDMA 24317

Skydrol

EPDM

Special “H”

For applications outside these parameters, please consult us!

Filter element (measured with mineral oil HLP46 according to DIN 51524)

Spec. weight: < 0.9 kg/dm3

Δp-Q characteristic curves for complete filter, recommended initial Δp for design = 2.5 bar

Selection of the perfect filter is made possible by our online “Bosch Rexroth FilterSelect“ design software.

320PZR06/025-H10PZ; 320PZL06/025-H10PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

320PZR10/075-H3PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

320PZR10/125-H3PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

320PZR06/025-H10PZ; 320PZL06/025-H10PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

320PZR10/075-H10PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

320PZR10/125-H10PZ

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter
technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Installation

The max. operating pressure of the system must not exceed the max. adm. operating pressure of the filter (see name plate). During assembly of the filter, the flow direction (inlet = bore P / sealing side) and the required servicing height of the filter element (see chapter “Dimensions”) are to be considered. Easy filter element exchange is guaranteed with the usual installation position - filter bowl horizontal  . The installation position - filter bowl upwards - is not admissible. The maintenance indicator must be arranged in a well visible way. Remove the protective foil at the filter inlet and outlet. The optional electric maintenance indicator is connected via the electronic switching element with 1 or 2 switching points, which is attached to the mechanical/visual maintenance indicator and held by means of the locking ring.

Commissioning

Commission the system.

 

Notice:

There is no bleeding provided at the filter.

Maintenance

If at operating temperature, the red indicator pin reaches out of the mechanical/visual maintenance indicator and/or if the switching process in the electronic switching element is triggered, the filter element is contaminated and needs to be replaced and cleaned respectively. The material number of the corresponding replacement filter element is indicated on the name plate of the complete filter. It must comply with the material number on the filter element. Decommission the system. The operating pressure is to be built up on the system side.

 

Notice:

There is no bleeding provided at the filter.

 

Screw off the filter bowl. Remove the filter element from the spigot by rotating it slightly. Clean the filter components, if necessary. Check the seals at the filter bowl for damage and renew them, if necessary. For suitable seal kits refer to chapter “Spare parts”. Install the new filter element on the spigot again by slightly rotating it. The filter is to be assembled in reverse order.

 

Please note:

Screw in the filter bowl to the stop, then screw out the filter bowl by 1/8 to 1/2 rotation again so that the filter bowl does not get stuck due to the pressure pulsation and can be easily released in case of maintenance works. The torque specifications (“Tightening torques” chapter) are to be observed. Commission the system.

Notice

Assembly and disassembly only with depressurized system! Filter is under pressure! Remove the filter bowl only if it is depressurized! Do not exchange the maintenance indicator while the filter is under pressure! If the flow direction is not considered during the assembly, the filter element will be destroyed. Particles will get into the system and damage downstream components.

Notes:

All works at the filter only be trained specialists. Functioning and safety are only guaranteed if original Bosch Rexroth filter elements and spare parts are used. Warranty becomes void if the delivered item is changed by the ordering party or third parties or improperly mounted, installed, maintained, repaired, used or exposed to environmental condition that do not comply with the installation conditions.

Tightening torques

Series

320PZR/PZL06/025

320PZR10/075

320PZR10/125

Filter bowl

Screw in filter bowl as far as it will go and unscrew 1/8 to 1/2 turn

Tightening torque maintenance indicator

Nm

max. 50

Tightening torque cubic connector screw
Switching element EN-175301-803

Nm

M3 / 0,5

Ordering code

Hydraulic fluid

Seal material

Element design

Mineral oil

HLP

DIN 51424

M

...0

Flame-resistant

Emulsion

HFA-E

DIN 24320

M

...0

Synthetic water solution

HFA-S

DIN 24320

M

...D

Water solution

HFC

VDMA 24317

M

...D

Phosphoric acid esters

HFD-R

VDMA 24317

V

...D

Organic esters

HFD-U

VDMA 24317

V

...D

Bio-degradable

Triglycerides (rape seed oil)

HETG

VDMA 24568

M

...D

Synthetic esters

HEES

VDMA 24568

V

...D

Polyglycols

HEPG

VDMA 24568

V

...D

Sealing kits must be ordered specifying the complete key.

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Sandwich plates

HSZ 06

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Sandwich plates

HSZ 06

Size 6 Maximum operating pressure 315 bar

Data sheet

Spare parts & repair

Electronic switching elements

WE-.SP

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Electronic switching elements

WE-.SP

Operating temperature -30 … +85 °C

Data sheet

Spare parts & repair

Electronic switching elements

WE-S02

Electronic switching elements

WE-S02

Max. operating pressure 40 bar Operating temperature -10 … +100 °C

Data sheet

Spare parts & repair

Pressure differential indicators for filters in pressure lines

WO-D01

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Pressure differential indicators for filters in pressure lines

WO-D01

Max. operating pressure 450 bar Operating temperature -30 … +100 °C

Data sheet

Spare parts & repair

Classification according to the Pressure Equipment Directive

The block mounting filter for hydraulic applications according are pressure holding equipment according to article 1, section 2.1.4 of the Pressure Equipment Directive 97/23/EC (PED). However, based on the exception in article 1, section 3.6 of the PEG, hydraulic filters are exempt from the PED if they are not classified higher than category I (guideline 1/19).

The fluids from the chapter “Compatibility with approved pressure fluids” were considered for the classification. They do not receive a CE mark.

 

Use in potentially explosive areas according to directive 94/9/EC (ATEX)

The block mounting filter according are not equipment or components in the sense of directive 94/9/EC and are not provided with a CE mark. It has been proven with the ignition risk analysis that these block mounting filters do not have own ignition sources acc. to DIN EN 13463-1:2009.

According to DIN EN 60079-11:2012, electronic maintenance indicators with a switching point:

WE-1SP-M12x1 and

WE-1SP-EN175301-803

are simple, electronic operating equipment that do not have an own voltage source. This simple, electronic operating equipment may ‒ according to DIN EN 60079-14:2012 ‒ in intrinsically safe electric circuits (Ex ib) be used in systems without marking and certification.

The block mounting filters and the electronic maintenance indicators described here can be used for the following explosive areas:

Zone suitability

Gas

1

2

Dust

21

22

Complete filter with mech./opt. maintenance indicator

Use/assignment

II 2D II 2G

Assignment

Ex II 2D c IIB TX Ex II 2G c IIB TX

Minimum conductivity of the medium

pS/m

300

Dust accumulation

max.

mm

0.5 -

Electronic switching element in the intrinsically safe electric circuit

Use/assignment

II 2D II 2G

Assignment

Ex II 2D Ex ib IIIC T100°C Db

Perm. intrinsically safe electric circuit

Ex ib IIIC Ex ib IIC, Ex ic IIC

Switching voltage Ui

max.

V AC/DC

150

Switching current Ii

max.

A

1

Switching power Pi

max.

750 mW Tmax 40 °C
550 mW Tmax 100 °C
1.3 W T4 Tmax 40 °C
1.0 W T4 Tmax 80 °C

Maximum surface temperature 1)

°C

100 -

Inner capacity Ci

neglectable

Inner inductivity Li

neglectable

Dust accumulation

max.

mm

0.5 -
1) The temperature depends on the temperature of the medium in the filter and must not exceed the value specified here.

Possible circuit according to DIN EN 60079-14

technical illustration-320PZR06/025-2X/H6PZB00-V8,0-M-Block mounted filter

Warning!

Explosion hazard due to high temperature! The temperature depends on the temperature of the medium in the hydraulic circuit and must not exceed the value specified here. Measures are to be taken so that in the potentially explosive area, the max. admissible ignition temperature is not exceeded. When using the filters in potentially explosive areas, appropriate equipotential bonding has to be ensured. The filter is preferably to be earthed via the mounting screws. It has to be noted in this connection that paintings and oxidic protective layers are not electrically conductive. Maintenance only by specialists, instruction by the machine end-user acc. to DIRECTIVE 1999/92/EC appendix II, section 1.1. During filter element exchanges, the packaging material is to be removed from the replacement element outside the potentially explosive area. Functional and safety warranty only applicable when using genuine Rexroth spare parts.