Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

SUN HYDRAULICS CORP
X6DCXANCA212
Circuit Savers

Y-assembly

SUN HYDRAULICS CORP

MATERIAL:  X6DCXANCA212

SUMMARY:  Y-assembly

Due to extremely high demand, please call 888-651-5712 for availability

This assembly consists of a fixed-orifice, pressure-compensated flow control valve with reverse flow check which provides precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at the factory. The rapid or feed rate is selected by a solenoid operated (normally open or closed) 2-way, 2-position valve.

  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • The tuneable control option provides +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
  • Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.

Capacity30 gpm120 L/min.
Body TypeSandwichSandwich
InterfaceISO 05ISO 05
Body FeaturesMeter in on B or meter out on AMeter in on B or meter out on A
Stack Height2.99 in.76 mm
Seal Plate Included (see notes)YesYes

Show FAQ

Additional Resources



Notes:
  • Stack height value in technical data table includes seal retainer plate.
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.